6850-00-069-2583

LITHOGRAPHIC FOUNTAIN SOLUTION


6850-00-069-2583 (6850000692583, 000692583)
Part Number (1 listing): 4-1014
Summary

FSG 68 / FSC 6850

DEMIL: A

DEMIL INT: 1

HMIC: Y

Date Created: 13 Jul 1967

Replacement NSN:

6850-00-181-7659

Replacement Date: 17 Oct 1979

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6850-00-069-2583 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
4-10143 - Design Control Reference2 - Production ItemABD INTL INC  17638      
4-10143 - Design Control Reference2 - Production ItemABD INTL INC  17638      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6850-00-069-2583 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
686850000692583T089-B17764XKAYA13 Jul 1967
Code Definitions

68

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Chemicals and Chemical Products

6850

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Miscellaneous Chemical Specialties

000692583

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6850-00-069-2583

T089-B

Federal Item Identification Guide (FIIG_4065)

17764

Item Naming Code (INC_4080)

13 Jul 1967

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

Y

Hazardous Material Indicator Code (HMIC_0865)


Indicates information is in the Hazardous Materials Information Resource System (HMIRS).

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG C - REFERENCE NUMBER | NSN 6850-00-069-2583 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
332475D4-1014  17638  
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

75

Reference Number Action Activity Code (RNAAC_2900)


GSA, FSS/FCSC Washington, DC 20406

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6850-00-069-2583 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
3CX61CX017 Oct 1979 6850001817659 13 Oct 1979
Code Definitions

3

Item Standardization Code (ISC_2650)


An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

1

Replaced / Replacement Item Standardization Code (ISC_2650)


An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.

0

Replaced / Replacement NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

17 Oct 1979

Date of Replacement Standardization Decision (DT_STDZN_DEC_2300)

6850-00-181-7659

Replaced / Replacement NSN (RP_NSN_STD_RL_8977 / RPLM_NSN_STDZ_9525)

13 Oct 1979

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6850-00-069-2583 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
57
Code Definitions

57

Originating Activity Code (ORIG_ACTY_CD_4210)


Health Services Administration, Perry Point, MD 21902

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6850-00-069-2583 Submit RFQ
MRCDecoded RequirementClear Text Reply
BBRCComposition And Percentage0.0002 MINIMUM BY VOLUME PONTAMINE BLUE ERR-100
BBRCComposition And Percentage0.0016 MINIMUM BY VOLUME PONTAMINE FAST TURQUOISE
BBRCComposition And Percentage1.0 MINIMUM BY VOLUME PHOSPHORIC ACID ERR-100
BBRCComposition And Percentage1.8 MINIMUM BY VOLUME DISODIUM ACID PHOSPHATE ERR-100
BBRCComposition And Percentage100.0 MINIMUM BY VOLUME WATER ERR-100
BBRCComposition And Percentage24.0 MINIMUM BY VOLUME GLYCERIN
BBRCComposition And Percentage8.0 MINIMUM BY VOLUME N-PROPYL ALCOHOL
ARABFinal FormREADY-TO-USE
CNFBPlate Material For Which DesignedMETAL


Back to Top
Back to Top