Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
MIL-PRF-25567 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | ![]() |
25567E TY I | 5 - Replaced / Discontinued | 2 - Production Item | GREEN GLOBE INDUSTRIES | 07XT7 | ![]() |
MIL-L-25567 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
MILL25567ATYPE1 | 5 - Replaced / Discontinued | 9 - No Longer Used | MILITARY SPECIFICATIONS | 81349 | ![]() |
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
68 | 6850 | 001850423 | T089-B | 27492 | X | 1 | A | Y | A | 22 Feb 1971 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates information is in the Hazardous Materials Information Resource System (HMIRS).
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
G940 | 0 | 0 | C | 1 Apr 1991 | ||||||||||||||||||||||||||
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
YJ01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZE01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZG01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZA01 | 1 Oct 1995 | |||||||||||||||||||||||||||||
ZP01 | 1 Jul 1996 | |||||||||||||||||||||||||||||
ZK01 | 1 Feb 1997 | |||||||||||||||||||||||||||||
ZH01 | 1 Mar 1997 | |||||||||||||||||||||||||||||
ZR01 | 1 Jul 1997 | |||||||||||||||||||||||||||||
YA01 | 1 Aug 2000 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 2005 | |||||||||||||||||||||||||||||
A917 | A184 | 1 | G | Z | CD | AM | BD | 1 May 2006 | ||||||||||||||||||||||
C911 | C006 | 1 | G | 1 May 2006 | ||||||||||||||||||||||||||
FPGG | FPCX | 1 | G | Z | SP | 1 May 2006 | ||||||||||||||||||||||||
MC41 | MC04 | 1 | G | Z | PA | 1 May 2006 | ||||||||||||||||||||||||
N9BG | N9GD | 1 | G | Z | HD | GT | KE | HX | HD | 1 May 2006 | ||||||||||||||||||||
WP01 | 1 Jul 2006 | |||||||||||||||||||||||||||||
ZU01 | 1 Mar 2008 | |||||||||||||||||||||||||||||
ZF01 | 1 Oct 2008 | |||||||||||||||||||||||||||||
ZM01 | 1 Feb 2015 |
Not Established
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
Detachment 3, WR-ALC, San Antonio, TX 78241-5803
Marine Corps Logistics Base, Albany, GA 31704-1128
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval ICP, Philadelphia, PA 19111
Navy ICP, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
U.S. Army Medical Materiel Agency, Frederick, MD 21701-5001
U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 1 | 3 | ZZ | MIL-PRF-25567 | 81349 | ![]() | ||||||
4 | 5 | 2 | 5 | 9Z | D | 25567E TY I | 07XT7 | ![]() | ||||
5 | 9 | 3 | 9Z | B | MIL-L-25567 | 81349 | ![]() | |||||
5 | 9 | 4 | ZZ | MILL25567ATYPE1 | 81349 | ![]() |
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
USA
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 20 May 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CX | 635 | Z | 9 | A | C | Z | W | 043940 | Z | 23310 | CHEMICALS-NOI |
Defense Supply Center Richmond, Richmond, VA 23297-5000
Chemicals, Other Than Drugs or Sundries
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Chemical corps items and all other chemicals not covered in other classifications. When chemical item (as indicated by the DOT Proper Shipping Name) is sensitive as defined in Appendix A Section I of DoD 4500.32-R, Volume I, second position must be from table 85, part 1.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DA | SMS | H | U | 1 | Z | GL | 7 | |
DF | SMS | H | U | 1 | N | GL | 7 | |
DM | SMS | H | U | 1 | Z | GL | 7 | |
DN | SMS | H | U | 1 | GL | 7 | ||
DS | SMS | H | U | 1 | N | GL | 7 | |
GP | SMS | H | U | 1 | GL | 7 | ||
DA | SMS | H | U | 1 | Z | GL | 7 | |
DF | SMS | H | U | 1 | N | GL | 7 | |
DM | SMS | H | U | 1 | Z | GL | 7 | |
DN | SMS | H | U | 1 | GL | 7 | ||
DS | SMS | H | U | 1 | N | GL | 7 |
Defense Logistics Agency, Enterprise Business Systems
DIRECT DELIVERY UNDER A CENTRAL CONTRACT # (VENDOR STOCKED) Issue, transfer or shipment is not subject to specialized controls other than those imposed by IMM/Service/Agency supply policy. 1. The item is centrally managed and procured. 2. Normal issue is by direct shipment from the vendor to the user at the order of the ICP or IMM. However, orders may be shipped from stock by ICP or IMM distribution facilities when the vendor's minimum order quantity is not met, or when stocks are being drawn down. 3. Requisitions and fund citations will be submitted in accordance with IMM/Service/Agency Requisitioning Procedures. 4. Generally delivery will be made within applicable Service/Agency guidelines addressing customer required timeframe.
Unclassified
1
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Gallon - Unit of liquid measurement
TYPE II (36 Months (3.00-Years)) - An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Army
Department of the Air Force
U.S. Marine Corps
Department of the Navy
Defense Logistics Agency
U.S. Coast Guard
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 10 | 1 | ZZZ | 8.8 lbs | 0.318 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | X | ZZ | ZZ | 33 | E | Q | M |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Physical protection
Any suitable process that is not injurious to the item.
No requirement
As required to protect the item or elements of the package
Special requirement – See specific instructions or drawings provided.
Special requirement – See specific instructions or drawings provided.
Type II, shelf life
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
BMRR | Active Ingredient | ANY ACCEPTABLE |
ZZZX | Departure From Cited Designator | AS MODIFIED BY UNIT PACKAGE QUANTITY,UNIT PACKAGE TYPE,QUANTITY WITHIN EACH UNIT PACKAGE |
ZZZT | Nondefinitive Spec/Std Data | I TYPE |
CXCY | Part Name Assigned By Controlling Agency | LEAK TEST COMPOUND LIQ 1GAL |
AKKF | Quantity Within Each Unit Package | 1.0 GALLONS |
AGXW | Physical Form | LIQUID |