Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
D4985 | 3 - Design Control Reference | 1 - Incomplete Part Number | AMERICAN SOCIETY FOR TESTING AND | 81346 | ![]() |
PRT ANTIFREEZE-55GL | 3 - Design Control Reference | 2 - Production Item | NUGENERATION TECHNOLOGIES, LLC | 1D6V1 | ![]() |
ANTIFREEZE | 3 - Design Control Reference | 2 - Production Item | RITE-KEM, INC. | 0VVN0 | ![]() |
A-18830255 | 3 - Design Control Reference | 2 - Production Item | MORNING STAR INDUSTRIES INC. | 1GDM9 | ![]() |
ANTIFREEZE | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | RITE-KEM, INC. | 0VVN0 | ![]() |
D3306 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | AMERICAN SOCIETY FOR TESTING AND | 81346 | ![]() |
ANTIFREEZE, ETHYLENE GLYCOL | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | CHEMICAL SPECIALISTS AND | 4N760 | ![]() |
CITGO ANTIFREEZE & COOLANT | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 | ![]() |
FULL FORCE ANTIFREEZE | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | OLD WORLD INDUSTRIES LLC | 0U3B1 | ![]() |
FULL FORCE ANTIFREEZE AND COOLA- | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | OLD WORLD INDUSTRIES LLC | 0U3B1 | ![]() |
ANTIFREEZE COOLANT INHIBITED | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | WYANDOTTE PAINT PRODUCTS CO | 88375 | ![]() |
D4340 | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | AMERICAN SOCIETY FOR TESTING AND | 81346 | ![]() |
FULL FOROE ANTIFREEZE | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | FEDERAL SPECIFICATIONS | 81348 | ![]() |
ANTIFREEZE, ETHYLENE GLYCOL | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | DYNACHEM TECHNOLOGIES INC | 1H3B5 | ![]() |
500-XL PERMANENT ANTI-FREEZE | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | BARTON CHEMICAL CORP | 2R684 | ![]() |
MCGUARD A.P. ANTIFREEZE | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | MACARTHUR PETROLEUM AND SOLVENT CO | 3R483 | ![]() |
SURE ANTIFREEZE | 5 - Replaced / Discontinued | 1 - Incomplete Part Number | PITT PENN OIL CO | 0A1G5 | ![]() |
ANTIFREEZE | 5 - Replaced / Discontinued | 2 - Production Item | RITE-KEM, INC. | 0VVN0 | ![]() |
O-A-548 | 5 - Replaced / Discontinued | 9 - No Longer Used | FEDERAL SPECIFICATIONS | 81348 | ![]() |
A-A-870 | 5 - Replaced / Discontinued | 9 - No Longer Used | FEDERAL COMMERCIAL ITEM DESCRIPTION | 58536 | ![]() |
A-A52624 | 5 - Replaced / Discontinued | 9 - No Longer Used | FEDERAL COMMERCIAL ITEM DESCRIPTION | 58536 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
68 | 6850 | 006641409 | T089-B | 05131 | X | 4 | 6 | A | Y | A | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates information is in the Hazardous Materials Information Resource System (HMIRS).
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C014 | 0 | 0 | 1 Apr 1991 | |||||||||||||||||||||||||||
G011 | 0 | 0 | 1 Apr 1991 | |||||||||||||||||||||||||||
G171 | 0 | 0 | 1 Apr 1991 | |||||||||||||||||||||||||||
G281 | 0 | 0 | 1 Apr 1991 | |||||||||||||||||||||||||||
G721 | 0 | 0 | 1 Apr 1991 | |||||||||||||||||||||||||||
G751 | 0 | 0 | 1 Apr 1991 | |||||||||||||||||||||||||||
G881 | 0 | 0 | 1 Apr 1991 | |||||||||||||||||||||||||||
G901 | 0 | 0 | 1 Apr 1991 | |||||||||||||||||||||||||||
G931 | 0 | 0 | 1 Apr 1991 | |||||||||||||||||||||||||||
G941 | 0 | 0 | 1 Apr 1991 | |||||||||||||||||||||||||||
MC14 | 0 | 0 | Z | PA | 1 Apr 1991 | |||||||||||||||||||||||||
N9QG | 0 | 0 | Z | HD | GT | KE | HD | 1 Apr 1991 | ||||||||||||||||||||||
X002 | 1 Apr 1991 | |||||||||||||||||||||||||||||
A194 | 0 | 0 | Z | CD | AZ | 1 Apr 1991 | ||||||||||||||||||||||||
B031 | 0 | 0 | 1 Apr 1991 | |||||||||||||||||||||||||||
B750 | 0 | 0 | 1 Jul 2002 | |||||||||||||||||||||||||||
ZU01 | 1 Aug 2005 | |||||||||||||||||||||||||||||
WP01 | 1 Aug 2005 | |||||||||||||||||||||||||||||
ZW01 | 1 Dec 2005 | |||||||||||||||||||||||||||||
ZX01 | 1 Jan 2014 |
Not Established
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Marine Corps Logistics Base, Albany, GA 31704-1128
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
Naval ICP, Philadelphia, PA 19111
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
U.S. Army Tank-Automotive and Armaments, Command, Warren, MI 48397-5000
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 1 | 6 | ZZ | D4985 | 81346 | ![]() | ||||||
3 | 2 | 4 | ZZ | ANTIFREEZE | 0VVN0 | ![]() | ||||||
3 | 2 | 4 | ZZ | A-18830255 | 1GDM9 | ![]() | ||||||
3 | 2 | 4 | ZZ | BPVCB | N1 ![]() | PRT ANTIFREEZE-55GL | 1D6V1 | ![]() | ||||
5 | 1 | 6 | ZZ | ANTIFREEZE, ETHYLENE GLYCOL | 1H3B5 | ![]() | ||||||
5 | 1 | 6 | ZZ | BPVCB | N1 ![]() | 500-XL PERMANENT ANTI-FREEZE | 2R684 | ![]() | ||||
5 | 1 | 6 | ZZ | BMGQB | N1 ![]() | MCGUARD A.P. ANTIFREEZE | 3R483 | ![]() | ||||
5 | 1 | 6 | ZZ | BPRJH | V5 ![]() | ANTIFREEZE, ETHYLENE GLYCOL | 4N760 | ![]() | ||||
5 | 1 | 6 | ZZ | CCKXW | H1 ![]() | SURE ANTIFREEZE | 0A1G5 | ![]() | ||||
5 | 1 | 6 | ZZ | FULL FORCE ANTIFREEZE | 0U3B1 | ![]() | ||||||
5 | 1 | 6 | ZZ | FULL FORCE ANTIFREEZE AND COOLA- | 0U3B1 | ![]() | ||||||
5 | 1 | 4 | ZZ | D3306 | 81346 | ![]() | ||||||
5 | 1 | 4 | ZZ | D4340 | 81346 | ![]() | ||||||
5 | 1 | 6 | ZZ | BFKLQ | N1 ![]() | FULL FOROE ANTIFREEZE | 81348 | ![]() | ||||
5 | 1 | 6 | ZZ | BFKLR | N1 ![]() | CITGO ANTIFREEZE & COOLANT | 81349 | ![]() | ||||
5 | 1 | 6 | ZZ | BFKLS | N1 ![]() | ANTIFREEZE COOLANT INHIBITED | 88375 | ![]() | ||||
5 | 1 | 4 | ZZ | ANTIFREEZE | 0VVN0 | ![]() | ||||||
5 | 2 | 4 | ZZ | ANTIFREEZE | 0VVN0 | ![]() | ||||||
4 | 5 | 9 | 3 | 75 | B | O-A-548 | 81348 | ![]() | ||||
4 | 5 | 9 | 3 | 75 | B | A-A-870 | 58536 | ![]() | ||||
5 | 9 | 3 | ZZ | B | A-A52624 | 58536 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USA
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
GSA, FSS/FCSC Washington, DC 20406
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 31 Jul 1970 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
580 | Z | 9 | A | C | Z | W | 042690 | Z | 22070 | ALCOHOL-AMYL-ETC |
Antifreeze
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Chemical corps items and all other chemicals not covered in other classifications. When chemical item (as indicated by the DOT Proper Shipping Name) is sensitive as defined in Appendix A Section I of DoD 4500.32-R, Volume I, second position must be from table 85, part 1.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DA | GSA | H | U | 0 | Z | DR | 7 | |
DM | GSA | H | U | 0 | Z | DR | 7 | |
DN | GSA | H | U | 0 | DR | 7 | ||
GP | GSA | H | U | 0 | DR | 7 | ||
TG | GSA | H | U | 0 | DR | 7 |
General Services Administration, Washington, D.C. 20406
DIRECT DELIVERY UNDER A CENTRAL CONTRACT # (VENDOR STOCKED) Issue, transfer or shipment is not subject to specialized controls other than those imposed by IMM/Service/Agency supply policy. 1. The item is centrally managed and procured. 2. Normal issue is by direct shipment from the vendor to the user at the order of the ICP or IMM. However, orders may be shipped from stock by ICP or IMM distribution facilities when the vendor's minimum order quantity is not met, or when stocks are being drawn down. 3. Requisitions and fund citations will be submitted in accordance with IMM/Service/Agency Requisitioning Procedures. 4. Generally delivery will be made within applicable Service/Agency guidelines addressing customer required timeframe.
Unclassified
No QUP
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Drum - A cylindrical container designed as an exterior pack for storing and shipping bulk materials, e.g., fuels, chemicals, powders, etc. Drums may be made of metal, rubber, polyethylene or plywood, or fibre with wooden, metal or fibre ends. *Requires a quantitative expression
TYPE II (36 Months (3.00-Years)) - An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Army
U.S. Marine Corps
Department of the Navy
U.S. Coast Guard
General Services Administration
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
APGF | Design Type | PERMANENT |
CMQL | Arctic Graded Feature | NOT INCLUDED |
AGXW | Physical Form | LIQUID |
AKKF | Quantity Within Each Unit Package | 55.0 GALLONS |
FEAT | Special Features | ETHYLENE GLYCOL BASED ANTIFREEZE SUITABLE FOR CAR AND TRUCK ENGINES, 100% CONCENTRATED, LOW SILICATE FORMULATION, COMPATIBLE WITH SUPPLEMENTAL COOLING ADDITIVES |