6920-01-370-5585

MODULE ASSEMBLY,PREAMPLIFIER-MIXER


6920-01-370-5585 (6920013705585, 013705585)
Part Numbers (2 listings): ADT00045-1 | 248635-1 |
Summary

FSG 69 / FSC 6920

DEMIL: C

DEMIL INT:

HMIC: N

Date Created: 25 Jan 1993

Unit Weight: 1.9 lbs

Unit Size: 12.5in x 8.3in x 3in

Unit Pack Cube: 0.180 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6920-01-370-5585 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
ADT00045-13 - Design Control Reference2 - Production ItemAPPLIED DATA TECHNOLOGY INC  0DNU9      
ADT00045-13 - Design Control Reference2 - Production ItemAPPLIED DATA TECHNOLOGY INC  0DNU9      
248635-15 - Replaced / Discontinued2 - Production ItemCUBIC DEFENSE APPLICATIONS, INC.  94987    CAGE 94987  
248635-15 - Replaced / Discontinued2 - Production ItemCUBIC DEFENSE APPLICATIONS, INC.  94987    CAGE 94987  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6920-01-370-5585 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
696920013705585A2390077777CM1CNA225 Jan 1993
Code Definitions

69

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Training Aids and Devices

6920

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Armament Training Devices

013705585

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6920-01-370-5585

A23900

Federal Item Identification Guide (FIIG_4065)

77777

Item Naming Code (INC_4080)

25 Jan 1993

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

C

Item Criticality (CRITL_CD_FIIG_3843)


The item has critical features such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

1

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name does not exist.

C

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Remove and/or demilitarize installed key point(s) as prescribed in DOD 4160.21-M-1 — Defense Demilitarization Manual, or lethal parts, components and accessories

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

2

ADPE Identification Code (ADPEC_0801)


Digital CPUs, ADP Central Processing Units for Computers. Represents only CPUs that accept information represented by digital impulses. Specifically, a device capable of performing sequences of arithmetic and logic operations (a program) not only on data but also on the program which is contained in its internal memory (storage) without intervention of an operator. NOTE: Digital refers to the representation of discrete numbers, symbols, and alphabetic characters by a predetermined, coded combination of electrical impulses. Excludes CPUs that have both analog and digital capability. (See code 3)


FLIS - SEG C - REFERENCE NUMBER | NSN 6920-01-370-5585 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
322ZZADT00045-1  0DNU9  
522ME248635-1  94987   CAGE/94987
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

ME

Reference Number Action Activity Code (RNAAC_2900)


Engineering Data Support Center, Hill AFB, UT 84056-5609


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6920-01-370-5585 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597625 Jan 1993
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

25 Jan 1993

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6920-01-370-5585 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SU65839AHZJ061700X34580ELEC-APPLIANCES-INSTRUMENTS-NOI
Code Definitions

SU

Originating Activity Code (ORIG_ACTY_CD_4210)


Ogden Air Logistics Center, Hill AFB, UT 84056-5609

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

3

Type Cargo Code (TYPE_CGO_CD_9260)


Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

J

Less Than Truckload (CLAS_RTNG_CD_2770)


100.2

061700

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34580

Uniform Freight Classification (UFC_CD_MODF_3040)

ELEC-APPLIANCES-INSTRUMENTS-NOI

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 6920-01-370-5585 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PPGX10001.9 lbs12.5in x 8.3in x 3in0.180 cu ft1.4 lbs9.5in x 3in x 1in
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00XNS00B39M
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

GX

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Preserve by Method 41 as follows: Items subject to damage by electromagnetic and electrostatic field forces shall be initially wrapped in material conforming to MIL-PRF-81705, Type III, or bags conforming to MIL-DTL-117, Type II, Class H, Style 2, or cushioned in material conforming to A-A-3129, Type I, Grade B or PPP-C-795, Class 2 or PPP-C-1797, Type II, to prevent bag puncture, and unit packed in a heat-sealed bag conforming to MIL-DTL-117, Type I, Class F, Style 1. Reclosable cushioned pouches conforming to MIL-DTL-81997, Type I or II, may be used in lieu of initial wrap or cushioning. Lead or terminal configurations for all items shall be maintained as manufactured without causing loads or stresses capable of causing damage to the item. Materials used to maintain item position and lead or terminal configuration shall permit item removal without damage to the item. Electrostatic discharge (ESD) sensitive caution labels shall be applied in accordance with MIL-STD-129.

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

000

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

1.9 lbs

Unit Pack Weight (UP_WT_5153)

12.5in x 8.3in x 3in

Unit Pack Size (UP_SZ_5154)

0.180 cu ft

Unit Pack Cube (UP_CU_5155)

1.4 lbs

Unpackaged Item Weight (UNPKG_ITM_WT_5157)

9.5in x 3in x 1in

Unpackaged Item Dimensions (UNPKG_ITM_DIM_5158)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

NS

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-1672, Type II, folding convoluted cushioning in reusable box.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

B

Unit Container Level Code (UNIT_CTNR_LVL_5168)


Unit container provides level B packing protection.

39

Special Marking Code (SP_MKG_CD_5169)


ESD sensitive electronic device requirements of MIL-STD-129 apply

M

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6920-01-370-5585 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGAVEnd Item IdentificationP4AM POD; AIR WARRIOR; AN/GSQ-T59; AN/GSQ-T60; P/N'S 46620005-1,46610005-1; DISPLAY AND DEBRIEFING SUBSYSTEM TRAINING
CRTLCriticality Code JustificationTEXT
TEXTGeneral Characteristics Item DescriptionSESITIVE ELECTRONIC DEVICE; ITEM C/O CABLE ASSY 2; HOUSING 1; CONNECTOR 1; BALANCED MIXER 1; AMPLIFER 1,ADAPTER 2


Back to Top
Back to Top