6940-00-841-1797

POWER SUPPLY


6940-00-841-1797 (6940008411797, 008411797)
Part Number (1 listing): 142C
Summary

FSG 69 / FSC 6940

DEMIL: B

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1962

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 6940-00-841-1797 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
142C3 - Design Control Reference2 - Production ItemTDK-LAMBDA AMERICAS INC.  89022    CAGE 89022  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 6940-00-841-1797 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
696940008411797A3990000740XM9BNU1 Jan 1962
Code Definitions

69

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Training Aids and Devices

6940

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Communication Training Devices

008411797

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 6940-00-841-1797

A39900

Federal Item Identification Guide (FIIG_4065)

00740

Item Naming Code (INC_4080)

1 Jan 1962

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 6940-00-841-1797 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Apr 1991
ZH011 Apr 1991
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 6940-00-841-1797 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TU028 Jun 1971
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TU

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

28 Jun 1971

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 6940-00-841-1797 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
M658Z9AHZM062900X35110RECTIFIERS-NOI-BATTERY-ELIMINATORS
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


M

Less Than Carload (LCL_CD_2760)


85

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

062900

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35110

Uniform Freight Classification (UFC_CD_MODF_3040)

RECTIFIERS-NOI-BATTERY-ELIMINATORS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 6940-00-841-1797 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKWCElectrical Power Source RelationshipOPERATING
CBBLFeatures ProvidedFILTER
ZZZVFsc Application DataTRAINER,RADAR TARGET SIMULATOR
CWGHOutput Current Rating200.0 DC MILLIAMPERES NOMINAL 1ST POWER OUTPUT
CWGHOutput Current Rating200.0 DC MILLIAMPERES NOMINAL 2ND POWER OUTPUT
CWGHOutput Current Rating200.0 DC MILLIAMPERES NOMINAL 7TH POWER OUTPUT
CWGHOutput Current Rating500.0 DC MILLIAMPERES NOMINAL 3RD POWER OUTPUT
CWGHOutput Current Rating500.0 DC MILLIAMPERES NOMINAL 4TH POWER OUTPUT
CWGHOutput Current Rating500.0 DC MILLIAMPERES NOMINAL 5TH POWER OUTPUT
CWGHOutput Current Rating500.0 DC MILLIAMPERES NOMINAL 6TH POWER OUTPUT
APPAOutput Voltage Rating15.0 DC VOLTS NOMINAL 4TH POWER OUTPUT
APPAOutput Voltage Rating30.0 DC VOLTS NOMINAL 3RD POWER OUTPUT
APPAOutput Voltage Rating-15.0 DC VOLTS NOMINAL 6TH POWER OUTPUT
APPAOutput Voltage Rating-7.5 DC VOLTS NOMINAL 7TH POWER OUTPUT
APPAOutput Voltage Rating45.0 DC VOLTS NOMINAL 2ND POWER OUTPUT
APPAOutput Voltage Rating7.5 DC VOLTS NOMINAL 5TH POWER OUTPUT
APPAOutput Voltage Rating75.0 DC VOLTS NOMINAL 1ST POWER OUTPUT
APNXInput Voltage Rating115.0 AC POUNDS PER HOUR WET SINGLE OPERATING POWER RQMT
APTQInput Frequency Rating60.0 HERTZ NOMINAL SINGLE OPERATING POWER RQMT
ANPMInput PhaseSINGLE SINGLE OPERATING POWER RQMT
ABKWOverall Height5.219 INCHES NOMINAL
ABHPOverall Length15.609 INCHES NOMINAL
ABMKOverall Width19.000 INCHES NOMINAL
FEATSpecial FeaturesFULL RECTIFICATION


Back to Top