7010-01-656-5655

SERVER GROUP,NETWORK


7010-01-656-5655 (7010016565655, 016565655)
Part Number (1 listing): F5-BIG-LTM-7250V
Summary

FSG 70 / FSC 7010

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 8 Jul 2016

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 7010-01-656-5655 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
F5-BIG-LTM-7250V3 - Design Control Reference2 - Production ItemF5 NETWORKS INC  1Q8K0      
F5-BIG-LTM-7250V3 - Design Control Reference2 - Production ItemF5 NETWORKS INC  1Q8K0      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 7010-01-656-5655 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
707010016565655A562C080333X43ANA08 Jul 2016
Code Definitions

70

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Automatic Data Processing Equipment (Including Firmware), Software, Supplies and Support Equipment

7010

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


ADPE System Configuration

016565655

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 7010-01-656-5655

A562C0

Federal Item Identification Guide (FIIG_4065)

80333

Item Naming Code (INC_4080)

8 Jul 2016

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 7010-01-656-5655 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZF011 Jul 2016
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 7010-01-656-5655 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43239ZDF5-BIG-LTM-7250V  1Q8K0  
432E9ZDF5-BIG-LTM-7250V  1Q8K0  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.


FLIS - SEG G - FREIGHT DATA | NSN 7010-01-656-5655 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
26
Code Definitions

26

Originating Activity Code (ORIG_ACTY_CD_4210)


Department of Justice, Washington, DC 20534

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 7010-01-656-5655 Submit RFQ
MRCDecoded RequirementClear Text Reply
CXCYPart Name Assigned By Controlling AgencyBIG-IP SYSTEM
FEATSpecial Features64-BIT TMOS; VIRTUALIZATION - 8; MEMORY - 32 GB; HARDDRIVE 400GB SOLID STATE DRIVE; GIGABIT ETHERNET CU PORTS 4; INPUT VOLTAGE - 90-240 VAC 50/60 HZ; TYPICAL HEAT OUTPUT 700 BTU/ HOUR; HEIGHT 3.45 INCHES; WIDTH 17.3 INCHES; DEPTH 21.4 INCHES; OPERATING TEMPERATURE 0 TO 40 DEGREES C


Back to Top
Back to Top