7021-01-579-6719

COMPUTER,DIGITAL


7021-01-579-6719 (7021015796719, 015796719)
Part Number (1 listing): 02-2800354-9
Summary

FSG 70 / FSC 7021

DEMIL: D

DEMIL INT: 1

HMIC: N

Date Created: 19 Nov 2009

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 7021-01-579-6719 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
02-2800354-93 - Design Control Reference2 - Production ItemGENERAL DYNAMICS C4 SYSTEMS, INC.  67032    CAGE 67032  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 7021-01-579-6719 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
707021015796719A519J062144X43DNDA419 Nov 2009
Code Definitions

70

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Automatic Data Processing Equipment (Including Firmware), Software, Supplies and Support Equipment

7021

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


ADP Central Processing Unit (CPU, Computer), Digital

015796719

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 7021-01-579-6719

A519J0

Federal Item Identification Guide (FIIG_4065)

62144

Item Naming Code (INC_4080)

19 Nov 2009

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

D

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

D

Electrostatic Discharge Code (ESD_EMI_CD_2043)


Represents items with both ESD and EMI sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

4

ADPE Identification Code (ADPEC_0801)


ADP Input/Output and Storage Devices Used to Control and Transfer Information to and from a CPU. The input device is used for transferring data and instructions into a CPU. The output device is used to transfer results of processing by the CPU onto printed forms, punched cards, and/or magnetic media. Input/output devices combine the above functions in the same device. This class also includes data transmission terminals, batch terminals, and display terminals which are specially designed or modified to be used in conjunction with digital, analog, or hybrid CPUs. It includes modems when they are integral to the terminal. It also includes storage devices in which data can be inserted, retained, and retrieved for later use.


FLIS - SEG B - MOE RULE DATA | NSN 7021-01-579-6719 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
A50200PNCN1 Nov 2009
MA46005NCN1 Feb 2013
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

P

Nonconsumable Item Material Support Code (NIMSC_0076)


Total depot maintenance is being accomplished by commercial contract.

N

Item Management Code (IMC_2744)


Modification/Alteration/Conversion Sets or Kits Intended for One-Time Use: This category covers situations in which such modification, alteration, or conversion sets or kits are procured for one time use, and replenishment or replacement is not contemplated. This category applies even when procurement occurs on a phased basis. Specifically, it retains under the management of the Service/Agency those sets or kits which requirements are properly determined on a program basis, such as the number of equipment to be modified.

5

Nonconsumable Item Material Support Code (NIMSC_0076)


Depot Reparable Component (Type II). This code identifies SICA managed depot reparable components assigned to another service which is responsible for the logistics functions of single submitter cataloger, acquisition and disposal authority, depot maintenance, and performs the wholesale stock, store, and issue functions and establishes, budgets, and funds the wholesale stock level requirement. Supply requirements will be submitted to the PICA on requisitions which are funded by a designated point within the SICA. Unserviceable SICA assets will normally be returned to the PICA for credit. The SICA will provide item/program data required by the PICA to meet the materiel support commitments. Normally, Military Interdepartmental Purchase Requests (MIPR) will not be requested by the PICA to support SICA NIMSC 5 requirements. The SICA CMD will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.

CNDSOR

Depot Source of Repair Codes (DSOR_0903)


Contract, Contiguous United States (CONUS)


FLIS - SEG C - REFERENCE NUMBER | NSN 7021-01-579-6719 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
323ZZ02-2800354-9  67032   CAGE/67032
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 7021-01-579-6719 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597019 Nov 2009
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

19 Nov 2009

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 7021-01-579-6719 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
CL
Code Definitions

CL

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 7021-01-579-6719 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DAB16HY1AEA0
DMMPBHY1DEA0
Code Definitions

B16

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


US Army Communications-Electronics, Command and Fort Monmout, Fort Monmouth, NJ 07703-5016

H

Acquisition Advice Code (AAC_2507)


DIRECT DELIVERY UNDER A CENTRAL CONTRACT # (VENDOR STOCKED) Issue, transfer or shipment is not subject to specialized controls other than those imposed by IMM/Service/Agency supply policy. 1. The item is centrally managed and procured. 2. Normal issue is by direct shipment from the vendor to the user at the order of the ICP or IMM. However, orders may be shipped from stock by ICP or IMM distribution facilities when the vendor's minimum order quantity is not met, or when stocks are being drawn down. 3. Requisitions and fund citations will be submitted in accordance with IMM/Service/Agency Requisitioning Procedures. 4. Generally delivery will be made within applicable Service/Agency guidelines addressing customer required timeframe.

Y

Controlled Item Inventory Code (CIIC_2863)


Communication/electronic equipment and parts

1

Quantity Unit Pack (QUP_6106)


1

A

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions. MARINE CORPS: Item requires special handling/or condemnation procedures because of specific reasons (i.e., precious metal content, high dollar value, critical material, or hazardous material). Refer to appropriate manuals/directives for specific instructions. NAVY: Field Activity Control Items

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

MPB

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Commanding General, Marine Corps Logistics Command, 566–2, Bldg. 3700, Albany, GA 31704-5000

D

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: When repair is beyond lower level maintenance capability, evacuate the item to depot. Disposal is not authorized below wholesale level; MARINE CORPS: Reparable item. When beyond lower level repair capability, return to depot. Condemnation and disposal not authorized below depot level; NAVY: Field Level Reparables

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DM

Service / Agency Code (MOE_CD_2833)


U.S. Marine Corps


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 7021-01-579-6719 Submit RFQ
MRCDecoded RequirementClear Text Reply
CYEDMemory Size2.0 GIGABYTES
ACYCProcessor Clock Speed2000.0 MEGAHERTZ
CXCYPart Name Assigned By Controlling AgencyTSC-750M MISSION PLANING FR EQUIVELANT CONFIGURATION (TSC_750M) V2 915 X 7000)
ABHPOverall Length11.000 INCHES NOMINAL
ABKWOverall Height4.000 INCHES NOMINAL
ABMKOverall Width12.000 INCHES NOMINAL
FEATSpecial FeaturesMILTOPE CHS PN 860011 INTEL PENTIUM PROCESSOR-2GHZ (533 FRONT SIDE BUS) 2GB RAM (EXTENDED TEMPERATURE),ATI 3-D GRAPHICS M26 WITH 256MB DEDICATED VIDEO RAM
AGAVEnd Item IdentificationCHS-III


Back to Top
Back to Top