7025-01-357-9855

DISK DRIVE UNIT


7025-01-357-9855 (7025013579855, 013579855)
Part Numbers (5 listings): 94601-12G | ST41200N | 91721698 | 005-037842 | 118-008516 |
Summary

FSG 70 / FSC 7025

DEMIL: D

DEMIL INT: 2

HMIC: N

Date Created: 6 May 1992

Unit Weight: 5.0 lbs

Unit Size: None

Unit Pack Cube: 1.000 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 7025-01-357-9855 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
94601-12G3 - Design Control Reference2 - Production ItemSEAGATE TECHNOLOGY  65867      
ST41200N3 - Design Control Reference2 - Production ItemSEAGATE TECHNOLOGY  65867      
917216985 - Replaced / Discontinued2 - Production ItemTHALES  F6481    CAGE F6481  
005-0378425 - Replaced / Discontinued2 - Production ItemDATA GENERAL CORP  6L443      
917216985 - Replaced / Discontinued2 - Production ItemTHALES TRAINING ET SIMULATION SAS  F6980    CAGE F6980  
118-0085165 - Replaced / Discontinued9 - No Longer UsedDATA GENERAL CORP  0AA57      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 7025-01-357-9855 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
707025013579855A505E037008X1DNA46 May 1992
Code Definitions

70

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Automatic Data Processing Equipment (Including Firmware), Software, Supplies and Support Equipment

7025

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


ADP Input/Output and Storage Devices

013579855

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 7025-01-357-9855

A505E0

Federal Item Identification Guide (FIIG_4065)

37008

Item Naming Code (INC_4080)

6 May 1992

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

D

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

4

ADPE Identification Code (ADPEC_0801)


ADP Input/Output and Storage Devices Used to Control and Transfer Information to and from a CPU. The input device is used for transferring data and instructions into a CPU. The output device is used to transfer results of processing by the CPU onto printed forms, punched cards, and/or magnetic media. Input/output devices combine the above functions in the same device. This class also includes data transmission terminals, batch terminals, and display terminals which are specially designed or modified to be used in conjunction with digital, analog, or hybrid CPUs. It includes modems when they are integral to the terminal. It also includes storage devices in which data can be inserted, retained, and retrieved for later use.


FLIS - SEG B - MOE RULE DATA | NSN 7025-01-357-9855 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZT016 May 1992
ZF011 Mar 1994
ZC0112 Sep 1994
ZH0124 Aug 1995
S041S0580051 Nov 1996
FJJ4F6CU00FEFZ1 Nov 1996
G73JG86000751 Nov 1996
NSJJ005EFZGG21 Oct 1997
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

5

Nonconsumable Item Material Support Code (NIMSC_0076)


Depot Reparable Component (Type II). This code identifies SICA managed depot reparable components assigned to another service which is responsible for the logistics functions of single submitter cataloger, acquisition and disposal authority, depot maintenance, and performs the wholesale stock, store, and issue functions and establishes, budgets, and funds the wholesale stock level requirement. Supply requirements will be submitted to the PICA on requisitions which are funded by a designated point within the SICA. Unserviceable SICA assets will normally be returned to the PICA for credit. The SICA will provide item/program data required by the PICA to meet the materiel support commitments. Normally, Military Interdepartmental Purchase Requests (MIPR) will not be requested by the PICA to support SICA NIMSC 5 requirements. The SICA CMD will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.

F

Nonconsumable Item Material Support Code (NIMSC_0076)


An activity within the Air Force is providing depot maintenance support.

E

Item Management Code (IMC_2744)


Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.

FZDSOR

Depot Source of Repair Codes (DSOR_0903)


Cryptologic Systems Group (CPSG), Lackland AFB, TX

75Collaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


GSA, FSS/FCSC Washington, DC 20406

GG

Supplementary Receivers (SUPPLM_RCVR_2534)


Naval Inventory Control Point, Philadelphia, PA 19111û5098


FLIS - SEG C - REFERENCE NUMBER | NSN 7025-01-357-9855 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
324ZZST41200N  65867  
524ZZ91721698  F6481   CAGE/F6481
4524ZFA91721698  F6980   CAGE/F6980
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

ZF

Reference Number Action Activity Code (RNAAC_2900)


France

A

Reference Number Status Code (RNSC_2923)


Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 7025-01-357-9855 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59706 May 1992
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

6 May 1992

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 7025-01-357-9855 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZTM73839AHQA116030A59295MACHINES-SYSTEMS-OR-DEVICES--DATA
Code Definitions

ZT

Originating Activity Code (ORIG_ACTY_CD_4210)


Norway

M

Less Than Carload (LCL_CD_2760)


85

738

Water Commodity Code (WRT_CMDTY_CD_9275)


Computing Equipment, Computer Components, and Circuit Cards

3

Type Cargo Code (TYPE_CGO_CD_9260)


Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Q

Air Special Handling Code (AIR_CMTY_HDLG_9215)


Extremely fragile items including delicate instruments.

A

Less Than Truckload (CLAS_RTNG_CD_2770)


400

116030

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

A

NMFC Sub Item Number (SUB_ITM_NBR_0861)

59295

Uniform Freight Classification (UFC_CD_MODF_3040)

MACHINES-SYSTEMS-OR-DEVICES--DATA

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 7025-01-357-9855 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFFPDV71TEA0
DNNRPV71HEA0
DFFPDY71TEA0
Code Definitions

FPD

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Air Force Cryptologic Support Group, 230 Hall Blvd, Bldg 2028, San Antonio, TX 78243-7081

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

7

Controlled Item Inventory Code (CIIC_2863)


Non-Sensitive (SRC-N/A) — UNCLASSIFIED AA&E or Items assigned a Demilitarization Code other than A, B, Q or P for which another CIIC is inappropriate. (NOTE: The loss, theft, unlawful 011disposition, and/or recovery of an item with CIIC 7 will be investigated in accordance with DoD 4000.25-2-M and DoD 7200.14–R, Volume 12, Chapter7).

1

Quantity Unit Pack (QUP_6106)


1

T

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

NRP

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098

H

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable

Y

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG W - PACKAGING DATA | NSN 7025-01-357-9855 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
ASAZZ10005.0 lbs1.000 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
XZZ00B39EFFA
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

S

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Secondary Inventory Control Activity (SICA)

A

Item Type Storage Code (ITM_TYP_STOR_5156)


Heated General Purpose – Heated 40 F and above

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

000

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

5.0 lbs

Unit Pack Weight (UP_WT_5153)

1.000 cu ft

Unit Pack Cube (UP_CU_5155)

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

ZZ

Unit Container Code (UNIT_CTNR_CD_5166)


Special requirement – See specific instructions or drawings provided.

00

Intermediate Container Code (INTMD_CTNR_CD_5167)


No requirement.

B

Unit Container Level Code (UNIT_CTNR_LVL_5168)


Unit container provides level B packing protection.

39

Special Marking Code (SP_MKG_CD_5169)


ESD sensitive electronic device requirements of MIL-STD-129 apply

E

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.

F

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing is not required: the unit container shall also serve as the shipping container. Closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

F

Packing Requirement Code - For Minimal Packing (MINM_PK_RQ_CD_5172)


Packing is not required; the unit container shall also serve as the shipping container. Closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

A

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Packaging is in accordance with a procedural specification or a SPI. The appropriate specification number will be shown in-the-clear in the supplemental data area.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 7025-01-357-9855 Submit RFQ
MRCDecoded RequirementClear Text Reply
CPLRUnit DesignINTERNAL
APGFDesign TypeHARD DISK
CYHNDrive Size5.25
CYFNDrive Quantity1
CYFPData Storage Capacity1.04 GIGABYTES
CYFQDrive HeightFULL
CYFRAccess Time In Milliseconds15.0
CYHQTransfer Rate In Megabytes Per Second2.8
CYECInterface TypeSCSI
CYFUTracks Per Inch1600.0
AWZJPower SourceEXTERNAL
CSBHVoltage In Volts And Current Type12.0 AC
FEATSpecial FeaturesSEAGATE HARD DISC DRIVE ST41200N, WREN 7 FULL HEIGHT, SCSI AND SCSI-2, THIN FILM, ZBR RLL (1,7). FORMATTED CAPACITY: 1037MB. AVERAGE SECTORS PER TRACK: 71. ACTUATOR TYPE: VOICE COIL. NBR TRACKS: 28965. NBR CYLINDERS: 1931. NBR HEADS: 15. NBR DISCS: 8. SPINDLE SPEED: 3600RPM. MTBF POWER ON HOURS: 150000. LANDING ZONE CYLINDER: AUTO PARK
AGAVEnd Item IdentificationCOMPUTER SYSTEMS


Back to Top
Back to Top