7025-01-516-5458

RECEIVER,DIGITAL DATA


7025-01-516-5458 (7025015165458, 015165458)
Part Number (1 listing): D-9745
Summary

FSG 70 / FSC 7025

DEMIL: A

DEMIL INT: 4

HMIC: N

Date Created: 9 Jan 2004

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 7025-01-516-5458 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
D-97453 - Design Control Reference2 - Production ItemMITEQ, INC.  33592      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 7025-01-516-5458 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
707025015165458A2390011466X42ANAA09 Jan 2004
Code Definitions

70

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Automatic Data Processing Equipment (Including Firmware), Software, Supplies and Support Equipment

7025

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


ADP Input/Output and Storage Devices

015165458

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 7025-01-516-5458

A23900

Federal Item Identification Guide (FIIG_4065)

11466

Item Naming Code (INC_4080)

9 Jan 2004

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

2

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


The approved item name applied to this item exists for use exclusively with the partial descriptive method of item identification - Miscellaneous Items Federal Item Identification Guide A239.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 7025-01-516-5458 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZF011 Jan 2004
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 7025-01-516-5458 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZDD-9745  33592  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 7025-01-516-5458 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59709 Jan 2004
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

9 Jan 2004

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 7025-01-516-5458 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

1D

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 7025-01-516-5458 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABHPOverall Length20.000 INCHES NOMINAL
ABMKOverall Width19.000 INCHES NOMINAL
ABKWOverall Height1.750 INCHES NOMINAL
FEATSpecial FeaturesCONNECTORS RF SMA FEMALE, RF MONITOR SMA FEMALE, IF BNC FEMALE, IF MONITOR BNC FEMALE, LO MONITORS SMA FEMALE, ALARM DE-9P, EXTERNAL REFERENCE BNC FEMALE, REMOTE INTERFACE DE-9S FOR RS485, RS422 AND RS232, IEEE-488 RECEPTACLE FOR GPIB, PRIMARY POWER INPUT IEC-320, REDUNDANCY BUS, OPTION 1 ONLY, DB-25S; FREQUENCY 70 PORM 20 MHZ; IMPEDANCE 75 OHMS; RETURN LOSS 70 PORM 20 MHZ 26 DB MIN, 140 PORM 40 MHZ 20 DB MIN; SIGNAL MONITOR M20 DBC NOM; INPUT LEVEL, NONDAMAGE, P20 DBM MAX; IMPEDANCE 50 OHMS; RETURN LOSS 70 PROM 20 MHZ 20 DB MIN, 140 PORM 40 MHZ 20 DB MIN; SIGNAL MONITOR M20 DBC NOM; POWER OUTPUT P10 DBM MIN AT 1 DB COMPRESSION POINT; GAIN P30 DB MIN; NOISE FIGURE 20 DB TYPICAL, 25 DB MAX
SUPPSupplementary FeaturesENVIRONMENTAL OPERATING AMBIENT TEMP 0-50 DEG C, RELATIVE HUMIDITY UP TO 95 PCT AT 30 DEG C, ATMOSPHERIC PRESSURE UP TO 10,000 FEET; NONOPERATING RELATIVE HUMIDITY UP TO 95 PCT AT 40 DEG C, ATMOSPHERIC PRESSURE UP TO 40,000 FEET, SHOCK AND VIBRATION NORMAL HANDLING BY COMMERCIAL CARRIERS; IMAGE REJECTION 80 DB MIN; LEVEL STABILITY PORM 0.25 DB/DAY MAX AT CONSTANT TEMP; AMPLITUDE RESPONSE 70 PORM 20 MHZ PORM 0.25 DB/PORM 20 MHZ, PORM 0.20 DB/PORM 18 MHZ; 140 PORM 40 MHZ 0.75 DB/76 MHZ; NOISE FIGURE 12 DB MAX; RF FREQUENCY 7.25-7.75 GHZ
FTLDFunctional DescriptionDESIGNED FOR ADVANCED SATELLITE COMMUNICATION SYSTEMS; PHASE NOISE, AMPLITUDE FLATNESS AND SPURIOUS OUTPUTS HAVE BEEN OPTIMIZED TO PROVIDE THE USER WITH A TRANSPARENT FREQUENCY CONVERSION; SUPPORTS POWERFUL LOCAL AND REMOTE CONTROL; A CONTINUOUSLY UPDATED LOG OF TIME-STAMPED RECORDS OF ACTIVITY; CAN OPERATE STAND ALONE OR CAN BE ARRANGED IN A REDUNDANCY CONFIGURATION WITHOUT THE NEED FOR A DEDICATED SWITCH CONTROL UNIT
CXCYPart Name Assigned By Controlling AgencyDOWNCONVERTER


Back to Top
Back to Top