7025-01-530-7767

INTERFACE UNIT,AUTOMATIC DATA PROCESSING


7025-01-530-7767 (7025015307767, 015307767)
Part Number (1 listing): 15601
Summary

FSG 70 / FSC 7025

DEMIL: B

DEMIL INT: 3

HMIC: N

Date Created: 10 Jun 2005

MSDS: None

Hazmat: None

Export License Required:
Critical Munitions List Item or Sensitive Commerce Control List Item

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 7025-01-530-7767 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
156013 - Design Control Reference2 - Production ItemEXTREME NETWORKS INC.  1G5W1      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 7025-01-530-7767 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
707025015307767A3080045109X46BNAA010 Jun 2005
Code Definitions

70

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Automatic Data Processing Equipment (Including Firmware), Software, Supplies and Support Equipment

7025

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


ADP Input/Output and Storage Devices

015307767

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 7025-01-530-7767

A30800

Federal Item Identification Guide (FIIG_4065)

45109

Item Naming Code (INC_4080)

10 Jun 2005

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

B

Demilitarization Code (DEMIL_CD_0167)


MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 7025-01-530-7767 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZN011 Jun 2005
ZR011 Jan 2014
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 7025-01-530-7767 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZD15601  1G5W1  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 7025-01-530-7767 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597010 Jun 2005
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

10 Jun 2005

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 7025-01-530-7767 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
80
Code Definitions

80

Originating Activity Code (ORIG_ACTY_CD_4210)


NASA Marshall Space Flight Center, Marshall Space Flight Center, AL 35812-0001

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 7025-01-530-7767 Submit RFQ
MRCDecoded RequirementClear Text Reply
ACUQAlternating Current Voltage Rating In Volts100.0 AND 240.0
AMPSCurrent Rating In Amps1.5 AND 3.0
FREQFrequency In Hertz50.0 AND 60.0
AAXXMounting TypeRACK
AWZJPower SourceEXTERNAL
FEATSpecial FeaturesFORTY-EIGHT 10/100 BASE-TX ETHERNET PORTS; 2 UNPOPULATED MINI-GBIC 1000 BASE-TX PORTS; BASIC LAYER 3 SWITCHING; SINGLE AC HOT SWAPPABLE POWER SUPPLY WITH POWER CORD


Back to Top
Back to Top