7310-00-401-6851

GRILL,ELECTRIC


7310-00-401-6851 (7310004016851, 004016851)
Part Number (1 listing): 3705
Summary

FSG 73 / FSC 7310

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 26 Nov 1969

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 7310-00-401-6851 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
37053 - Design Control Reference2 - Production ItemUNIVERSAL ELECTRIC CO  62119      
37053 - Design Control Reference2 - Production ItemUNIVERSAL ELECTRIC CO  62119      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 7310-00-401-6851 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
737310004016851A505K005274X46ANA26 Nov 1969
Code Definitions

73

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Food Preparation and Serving Equipment

7310

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Food Cooking, Baking, and Serving Equipment

004016851

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 7310-00-401-6851

A505K0

Federal Item Identification Guide (FIIG_4065)

05274

Item Naming Code (INC_4080)

26 Nov 1969

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 7310-00-401-6851 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
CCX66 Aug 1978
Code Definitions

C

Item Standardization Code (ISC_2650)


An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

6

NIIN Status Code (NIIN_STAT_CD_2670)


Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.

6 Aug 1978

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 7310-00-401-6851 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

04

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 7310-00-401-6851 Submit RFQ
MRCDecoded RequirementClear Text Reply
ACDCCurrent TypeAC
AMSEVoltage Rating110.0 VOLTS NOMINAL
ABHPOverall Length10.500 INCHES NOMINAL
ABKWOverall Height5.500 INCHES NOMINAL
FEATSpecial FeaturesWAFFLE GRIDS INCLUDED; EQUIPPED W/GREASE DRAIN; 6 FT LG ELECTRICAL CORD


Back to Top