Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
QQA200-8 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | FEDERAL SPECIFICATIONS | 81348 | |
QQA200-8 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | FEDERAL SPECIFICATIONS | 81348 |
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
95 | 9530 | 004576045 | A13100 | 37006 | X | 1 | A | N | U | 12 Sep 1969 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 4 | 1 | 3 | 75 | D | QQA200-8 | 81348 |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.
GSA, FSS/FCSC Washington, DC 20406
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
3 | KZ | 6 | 1 | KZ | 0 | 25 Mar 1989 | 9530002449021 | 23 Mar 1989 |
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Defense Supply Center Philadelphia, Philadelphia, PA 19101
Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
42 |
Department of Commerce, Gaithersburg, MD 20760
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AGTA | Basic Shape Style | FLAT |
ADWH | Cross-Sectional Width | 3.000 INCHES NOMINAL |
ADVM | Cross-Sectional Thickness | 1.0000 INCHES NOMINAL |
AARN | Fabrication Method | EXTRUDED |
HEAT | Heat Treatment | T-6510 SOLUTION HEAT TREATED AND STRESS RELIEVED BY STRETCHING |
MDCL | Material Document And Classification | QQ-A-200/8 FED SPEC 1ST MATERIAL RESPONSE |
MATT | Material | ALUMINUM ALLOY 6061 OR ALUMINUM ALLOY 6062 |
ZZZT | Nondefinitive Spec/Std Data | T6510 TEMPER |
ABRY | Length | 10.000 FEET MINIMUM AND 12.000 FEET MAXIMUM |
BRFD | Weight Per Unit Measure | 3.520 POUNDS PER LINEAR FOOT |