9540-01-475-0908

BEAM,STRUCTURAL


9540-01-475-0908 (9540014750908, 014750908)
Part Number (1 listing): CVC10031-19CA
Summary

FSG 95 / FSC 9540

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 22 May 2000

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 9540-01-475-0908 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
CVC10031-19CA3 - Design Control Reference2 - Production ItemTRIUMPH AEROSTRUCTURES, LLC  80378    CAGE 80378  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 9540-01-475-0908 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
959540014750908A1310037018X1ANA022 May 2000
Code Definitions

95

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Metal Bars, Sheets, and Shapes

9540

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Structural Shapes, Nonferrous Base Metal

014750908

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 9540-01-475-0908

A13100

Federal Item Identification Guide (FIIG_4065)

37018

Item Naming Code (INC_4080)

22 May 2000

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 9540-01-475-0908 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FNN5FGKZ00B1 Jun 2003
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

B

Item Management Code (IMC_2744)


Performance Based Logistics or Contractor Logistics Support: Consumable items that are unique to a weapon system which have been included in a Performance Based Logistics (PBL) or Contractor Logistics Support (CLS) contract. (PICA LOA must be 06 or 23).


FLIS - SEG C - REFERENCE NUMBER | NSN 9540-01-475-0908 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32EZZCVC10031-19CA  80378   CAGE/80378
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

E

Document Availability Code (DAC_2640)


The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 9540-01-475-0908 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597022 May 2000
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

22 May 2000

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 9540-01-475-0908 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
KH
Code Definitions

KH

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Industrial Supply Center, Philadelphia, PA 19111

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 9540-01-475-0908 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFF59JU0NFT0
DFF59JU0FT0
Code Definitions

F59

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Northrop Grumman IS ACS, FOR DEPOT STORAGE ONLY, 6401 S. Air Depot Blvd., Oklahoma City, OK 73135-5911

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

0

Quantity Unit Pack (QUP_6106)


No QUP

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

FT

Unit of Issue (UI_3050)


Foot - Unit of linear measurement, sometimes expressed as “linear foot”.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 9540-01-475-0908 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGTABasic Shape StyleH SHAPE
AARNFabrication MethodANY ACCEPTABLE
CMZYFirst Tip StyleSQUARE END
AGAVEnd Item IdentificationINTERMEDIATE; AIRCRAFT, B-2 BOMBER (ATB)
MDCLMaterial Document And ClassificationQQ-A-430, ALLOY 7075 FED SPEC 1ST MATERIAL RESPONSE
MATTMaterialALUMINUM ALLOY 7075
BPXFLeft Side Bottom Flange Distance To Center Of Both Flanges0.900 INCHES NOMINAL
ADXJLeft Side Flange Height1.800 INCHES NOMINAL
CTBRLeft Bottom Inside Angle90.0 DEGREES NOMINAL
ADXLLeft Side Flange Thickness0.188 INCHES NOMINAL
BPXDLeft Side Top Flange Distance To Center Of Both Flanges0.900 INCHES NOMINAL
CSMZLeft Top Inside Angle90.0 DEGREES NOMINAL
ABRYLength10.000 FEET MINIMUM AND 12.000 FEET MAXIMUM
BPXHRight Side Bottom Flange Distance To Center Of Both Flanges0.900 INCHES NOMINAL
ADXKRight Side Flange Height1.800 INCHES NOMINAL
ADXMRight Side Flange Thickness0.125 INCHES NOMINAL
BPXGRight Side Top Flange Distance To Center Of Both Flanges0.900 INCHES NOMINAL
CRZCRight Top Inside Angle90.0 DEGREES NOMINAL
CWKKRight Bottom Inside Angle90.0 DEGREES NOMINAL
CNQJSecond Tip Relationship To First TipIDENTICAL
ABMKOverall Width1.000 INCHES NOMINAL
BPXNWeb Flange Thickness0.125 INCHES NOMINAL


Back to Top
Back to Top