PS Magazine - TB 43-PS-617

PS, The Preventative Maintenance Monthly

ISSUE 617

APRIL 2004

PS Magazine - TB 43-PS-617 - Page 31 of 33
Some LAMS Pointers
PS 617
59
APR 04
58
50-0011
59-0003
50-0055
50-3603
50-0835
55-1251G
50-0064
50-0065
150-0001
50-0435
500744
50-0345
50-0373
50-0544
50-0090
50-0037
50-0032
50-0082
50-3215
Part #
NSN
Item
End rain gutter
Type 2 personnel door
Personnel door, flap pair
Pull through rope, 3/8 inches
Winch upgrade kit
Door ground seal
Door spacer, 18 inches
Door spacer, 27 inches
Wall fan
Exit light
Rain seal
Angled anti-rotator plate
Center anti-rotator plate
Hurricane kit bracket
Terminator bracket
Roller assembly
Pulley assembly
Hand operated winch
Button end cable, 110’ x 1/4”
50-0639
50-0002
50-0059
50-0061
50-0087
50-0205
50-0040
50-3294
50-0027
50-0437
50-0054
50-0251
50-2019
50-0248
50-0093
50-0237
50-0060
50-0021
50-0228
Part #
NSN
Item
Tiedown strap
Mounting bracket, shear cable
Safety cable, 119.75 inches long
Safety cable, 178.25 inches long
Purlin hinge assembly
Light fixture
Rain gutter
Button end cable, 170’ x 1/4”
Pivot pin
External beam cover, 6 inches
Internal beam cover
Beam nut with eye bolt
Valve plug
Helical extension spring
Rain gutter bracket
Terminator cable with eye
Safety cable, 149 inches long
Baseplate
High wind line assy
…so
clip it
and keep
it handy.
Winds can lift an open shelter and
send it sailing like a kite. To help your
LAMS survive high winds, make sure
all high wind lines, NSN 8340-01-463-
9858, are fastened. And close the end
doors and secure them with tiedown
straps, NSN 5340-01-463-7337. In fact,
it’s a good idea to always secure closed
doors with tiedown straps.
Zippers are put on fabric panels to
help with installation. They aren’t meant
to be opened and used as an exit. That’s
why the zippers on end door panels
should remain closed at all times.
Use bungee cords, NSN 4020-01-463-
7339, to secure end door fabric panels.
Here’s a
collection of
tips for setting
up and using
your LAMS…
don’t
let go!
When setting up on concrete surfaces,
use the Hilti Kwik Bolt II for installing
mounting plates, NSN 5340-01-326-5135,
and hurricane kit brackets, NSN 5410-01-
469-1941. The Kwik Bolt II is a long
thread bolt that measures 3/4” x 5 1/2”.
Order them from Hilti, Inc. with their Item
Number 00331961. You’ll get a box of 20
bolts. To order, call 1-800-950-6119. Or
you can send an email to:
usgovt@us.hilti.com
Kwik Bolt II
You
won’t
find
this parts
list in any
tm…
617. 58-59 (C)
2/28/04
1:08 PM
Page 1


Back to Top
Back to Top