PS Magazine - TB 43-PS-623

PS, The Preventative Maintenance Monthly

ISSUE 623

OCTOBER 2004

PS Magazine - TB 43-PS-623 - Page 25 of 33
PS 623
OCT 04
47
M12A1 Decon…
Dear Editor,
Here at the Chemical School, we M12A1 decon instructors give our stu-
dents these three tips for better deconning:
Idling
-
The M12 TM says
to idle down the decon for at
least 15 minutes at shutdown
so it can cool down. But it
doesn't say at what rpm.
We've found 1,500 to
2,000 rpm is the best idling
range. If it's lower, the engine
will stall.
Lubing
-
When you're doing
your quarterly lubing accord-
ing to LO 3-4230-209-10,
make extra sure to hit Valve
#1 with GAA. We've found
the valve breaks if it doesn't
get regular lubing. Anytime #1
turns hard, give it a shot of
GAA. In fact, do that with
any of the four valves.
Diesel
-
If you have an M12
with the new diesel engine,
remember it has different
idling and operating rpm
requirements than the gas
engine. See TM 3-4230-
237-10, the TM for the
diesel M12, for details.
SSG Annie Reyes
US Army Chemical School
Ft Leonard Wood, MO
(Editor's note:
You're sure not conning us
with those excellent decon suggestions,
Sergeant. Thanks for sharing.)
Idle
between
1,500 and
2,000 rpm
Don’t forget
Valve #1 when
lubing
you better
not
idle me
like the
old
m12!
hey, this
seargeant has
some
good
stuff
here.
pay attention
to these tips!
Power
Plants
and
Units…
Generators
(2 each)
NSN
6115-01-
5-kW, 60-Hz
5-kW, 60-Hz
5-kW, 60-Hz
10-kW, 60-Hz
10-kW, 400-Hz
15-kW, 400-Hz
30-kW, 50/60-Hz
30-kW, 50/60-Hz
60-kW, 50/60-Hz
60-kW, 50/60-Hz
60-kW, 50/60-Hz
60-kW, 400-Hz
313-4216
414-9697
313-4215
299-6035
313-4214
299-6034
299-6033
474-3783
303-7896
474-3776
322-8583
322-8582
Item
(Power plant)
AN/MJQ-35
AN/MJQ-35A
AN/MJQ-36
AN/MJQ-37
AN/MJQ-38
AN/MJQ-39
AN/MJQ-40
AN/MJQ-40B
AN/MJQ-41
AN/MJQ-41B
AN/MJQ-42
AN/MJQ-43
Trailer
M116A3
HMT
M103A3/A4
M103A3/A4
M103A3/A4
M200A1 (2 trailers)
M200A1 (2 trailers)
M200A1 (2 trailers)
M200A1 (2 trailers)
M200A1 (2 trailers)
M116A3
M116A3
LIN
P28083
P28083
P28151
P42262
P42330
P42614
P42126
P42126
P42194
P42194
P42466
P42534
Generator
NSN
6115-01-
5-kW, 60-Hz
5-kW, 60-Hz
10-kW, 60-Hz
10-kW, 60-Hz
10-kW, 400-Hz
10-kW, 400-Hz
15-kW, 400-Hz
15-kW, 50/60-Hz
15-kW, 50/60-Hz
15-kW, 50/60-Hz
30-kW, 50/60-Hz
30-kW, 50/60-Hz
30-kW, 400Hz
30-kW, 400Hz
60-kW, 50/60-Hz
60-kW, 50/60-Hz
60-kW, 400-Hz
60-kW, 400-Hz
100-kW, 50/60-Hz
200-kW, 50/60-Hz
332-0741
413-3820
319-9032
413-3818
313-4283
413-3819
317-2137
319-9033
413-3821
317-2138
317-2136
470-3673
317-2135
471-1507
317-2134
471-1508
317-2133
471-1506
417-7088
417-7085
Item
(Power unit)
PU-797
PU-797A
PU-798
PU-798A
PU-799
PU-799A
PU-800
PU-801
PU-801A
PU-802
PU-803
PU-803B
PU-804
PU-804B
PU-805
PU-805B
PU-806
PU-806B
PU-807
PU-809
Trailer
M116A3
HMT
M116A3
HMT
M116A3
HMT
M200A1
M116A3
HMT
M200A1
M200A1
M200A1
M200A1
M200A1
M200A1
M200A1
M200A1
M200A1
M1061E1
M1061E1
LIN
G42238
G42238
G42170
G42170
G53403
G53403
G78203
G78374
G78374
G53778
G35851
G35851
G35919
G35919
G78306
G78306
G17460
G17460
Z67207
Z15138
Who’s
Got the Power?
Decontaminating
M12
Problems
Power
plants (PP)
have
two
generators.
Power
units (PU)
have
one.
THESE TWO CHARTS
SHOW the configura-
tions for all the
power plants and
power units…
Designations and
trailers on power
plants and power
units can be
confusing.
don’t
be confused!
623.46-47(C)
8/23/04
6:35 PM
Page 1
Click here for a copy of this article to email to a friend
Click here for a copy of this article to email to a friend


Back to Top
Back to Top