G
ood news for you Bradley and MLRS crewmen. PS Magazine and various newsletter articles
are now available for access on the Army Knowledge Online (AKO) website.
That makes it very easy to log on and search for specific subjects or read about current
updates.
If you’re not already an AKO member, sign up for access at:
After you’ve logged on, click on the Files icon at the top of the page. In the left-hand col-
umn on the next screen, click on U.S. Army Organizations, then AMC on the main screen, fol-
lowed by TACOM.
Select the block next to Bradley - MLRS and click Subscribe at the top of the page. Click on
Bradley - MLRS, then Instructions and finally on Instructions
1. This opens a PDF file that
tells how to access all the Bradley and MLRS articles.
Bradley/MLRS Now on AKO
PS 630
MAY 05
6
PS 630
MAY 05
7
M1A2
SEP Tank…
I
f your M1A2 SEP still has any of the older
Army embedded GPS receiver (AEGR) circuit
or 110100), don’t play the hand you were dealt.
Any older AEGR cards found in the turret
mission processing unit (TMPU) and the
improved launch electronics control unit
(ILECU) during repair should be turned in now!
Those cards need to be upgraded to the new ver-
Not sure which cards are in your vehicle?
Here’s how to check your M1A2 SEP with soft-
ware vesion 4.0.
Turn in unserviceable cards following your regular turn-in procedures. Your
TACOM LAR can help.
Questions? Contact TACOM-RI’s Alan Shannon, DSN 793-0125 or (309) 782-
0125, or James Barber, DSN 793-6632 or (309) 782-6632.
Or send an email to:
alan.sherman@us.army.mil
or
james.j.barber@us.army.mil
C/W
SW
STATUS
SW
STATUS
SYSTEM
DATA
RETURN
STATUS
W00
C00
PV 5050 5080
HDG 270
120834:26Z
MAINTENANCE/BACKUP
L
REAR
R
RPM
26.5 V
MASTER
POWER
C 01
STATUS
DIAG
HULL
CB
CMDR
BACKUP
CMDR
ELCT
ON
OFF
RETURN
W 01
F
E
0
-
+
DIAG pushbutton
Turret
power
Master
power
1.
Make sure the tank’s MASTER
POWER and TURRET POWER are on.
2.
Press the DIAG push button on
the Commander’s display unit (CDU)
to enter the diagnostic menu.
3.
Press the STATUS pushbutton
to enter the status menu.
4.
Press the SW
STATUS push-
button to enter
the software
status menu. If
the screen
shows an AEGR
software version
of 2.2.2 or
below, you need
a replacement
AEGR card.
Ask for a
Re-deal
hey!
it
says here
we can
access
bradley
and MLRS
articles
on ako!
all right!
let’s check
it out!!
Questions? Contact the Bradley/MLRS
Mobility Group at DSN 786-8289 or (586)
574-8289 or send an email to:
BradleyMLRS@tacom.army.mil
630.06-07(C)
4/4/05
11:35 AM
Page 1
Click here for a copy of this article to save or to email