PS Magazine - TB 43-PS-720

PS, The Preventative Maintenance Monthly

ISSUE 720

NOVEMBER 2012

PS Magazine - TB 43-PS-720 - Page 32 of 33
60
PS 720
NOV 12
Body copy
STATEMENT OF OWNERSHIP, MANAGEMENT AND CIRCULATION
Title of Publication:
± PS,±The±Preventive±Maintenance±Monthly
Publication±No.±341-0950
Date of Filing:
±25±Sep±12
Frequency of Issue:
±Monthly
No. of Issues Published Annually:
±12
Annual Subscription Price:
± Domestic±$45.00±Foreign±$63.00
Complete Mailing Address of Publication:
± USAMC±Logistics±Support±Activity,±PS±Magazine
± 5307±Sparkman±Circle,±AMXLS-GP
± Redstone±Arsenal,±AL±35898-5000
Complete Mailing Address of Headquarters or
General Business Office of Publisher:
± Department±of±the±Army
± The±Pentagon
± Washington,±DC±20310
Publisher:
±Department±of±the±Army
Editor:
±JONATHAN±W.±PIERCE
Managing Editor:
D.±BRUCE±COTTON
Known Bondholders, Mortgagees, and Other Security Holders
Owning or Holding 1 Percent or More of Total Amount of Bonds,
Mortgages, or other Securities:
None
Tax Status: The purpose, function, and nonprofit status of this
organization and the exempt status for federal income tax purposes
±
has±not±changed±during±the±preceding±12±months.
Extent±and±Nature
of±Circulation
a.
Total±#±copies
b.(1)
±Subscriptions
b.(4)
±Other±USPS
c.
±Total±paid±distrib
d.(3)
Free±through±USPS
d.(4)
±Other±free
e.
±Total±free
f.
±Total±distribution±
g.
Copies±not±distributed
h.
±Total
i.±Percent±paid
Last±year
49,496
48,163
194
48,357
271
180
451
48,808
688
49,496
99.1%
Last±issue
(Oct±12)
48,280
47,255
225
47,480
140
57
197
47,677
603
48,280
99.6%
Submitted by:
STUART±A.±HENDERSON,±Production±Manager
Connie's
post
scripts
Connie's
POST
SCRIPTS
Turn in Launcher,
Smoke Generator
If± your± unit± still± has± the± M202± rocket± launcher±
(NSN± 1055-00-021-3909,± LIN± L45250)± or± the±
M3A3/A4± smoke± generator± (NSN± 1040-01-143-
9506,± LIN± J30492),± turn± them± in± as± is.± They± are±
obsolete.±If±you±have±the±M157±smoke±generator±
(NSN± 1040-01-406-7401,± LIN± G51840),± it’s± being±
pulled±from±the±field,±too,±and±made±obsolete.±If±
you±still±have±a±smoke±mission,±your±MTOE±should±
be± changed± to± the± M56± smoke± generator,± NSN±
1040-01-380-1400,±or±M58±smoke±generator,±NSN±
±
Questions?±Contact±TACOM’s±Ramon±Perez±at±
DSN±786-1553,±(586)±282-1553,±or±email:
ramon.j.perez.civ@mail.mil
Hood Takes Home
DOD
Gold
PS±sends±out±a±hearty±
“HOOAH!”
±to±1st±Sqdn,±3rd±Armored±Cav±
Regt,±Ft±Hood,±TX±(FORSCOM).±They±are±the±2012±Department±
of±the±Army±winner±of±the±Secretary±of±Defense’s±Maintenance±
Award± in± the± large± category± for± field-level± maintenance.± The±
annual±awards±recognize±outstanding±maintenance±efforts±across±
the±Department±of±Defense.
Updated Email
Address for UTAP
TACOM’s Unit Training Assistance Program
(UTAP) has a new email address for customer
support. This replaces a prior email change we
ran on Page 60 of PS 710. Email UTAP at:
usarmy.detroit.tacom.mbx.ilsc-utap@mail.mil
Return CBPS Overpack Box
When the Chemical Biological Protective
Shelter (CBPS) system comes back from
RESET at Pine Bluff Arsenal, it’s being
sent with a special overpack box. The
box protects CBPS basic issue items
and other equipment during shipment.
The box is expensive and difficult to
get, which is why you need to send the
overpack box back to Pine Bluff. That
way it can be reused with other CBPS
systems. Directions for returning the box
come with the CBPS. Questions? Contact
TACOM’s Mark Oldham at DSN 786-1687,
(586) 282-1687, or email:
mark.a.oldham6.civ@mail.mil
ElastiC Cord for
TruCk Covers
If± your± truck± uses± black± elastic± (bungee)±
cord±to±secure±its±cargo±and±cab±covers,±you±
can±replace±the±cord±as±it±wears±out.±NSN±
4020-01-463-8181±brings±280±feet±of±bulk±
cord±with±a±diameter±of±
1
/
4±to±
3
/
8±inches.
HMMWV 400-AMP Alternator
Need±NSNs±for±your±unit’s±M1151,±M1152,±M1165±and±M1167±HMMWV’s±400-AMP±alternator±
and± the± kit± that± comes± with± it?± We± can± help.± NSN± 2920-01-466-1855± brings± the± 400-AMP±
alternator.±You’ll±also±have±to±order±the±engine±generator±parts±kit,±NSN±2920-01-509-4688,±to±
install±the±new±alternator.±
5-, 10-, 15-kW TQG Contactors for Free
If you have a 5-, 10- or 15-kW tactical quiet generator (TQG), it may have a faulty K1 contactor,
NSN 6110-01-367-8921. If the contactor fails, there’s no power output to the load terminals.
Faulty contactors have a brown label with AMETEK printed on it. Look for the MFG DATE (date
of manufacture) on the label. The first number is the week, and the second number is the year.
Contactors with MFG DATEs from 40/10 through 13/11 have been identified as potentially
faulty. If you have a faulty K1 contactor, get a
replacement free of charge
by contacting
CECOM LCMC’s Nicole Archibald at DSN 648-4757, (443) 395-4757, or email:
nicole.archibald.civ@mail.mil
M870A3 Retrofit Kit for M983A2/A4 HEMTTs
Some±early±production±M870A3±semitrailers±were±built±with±an±electrical±system±compatible±
with±M916-series±tractor±trucks.±But±when±hooked±up±to±an±M983A2±or±M983A4±light±equipment±
transporter±HEMTT,±no±power±is±supplied±to±the±semitrailer’s±service±lighting±system±and±ABS±
electronic±control±unit.±Fix±that±by±installing±the±electrical±system±retrofit±kit,±NSN±5995-01-598-
1931.±That±keeps±your±semitrailer±fully±compatible±with±M916-series±tractor±trucks.±
720 60-61.indd
1-2
10/2/12
5:11 PM
Click here for a copy of these articles to save or email.


Back to Top
Back to Top