± Dispose± of± unserviceable± helmet± mounts± at± your± local± Defense± Logistics± Agency± (DLA)±
Disposition± Services± (formerly± DRMO).±
Do not
± send± unserviceable± mounts± to± Tobyhanna±
Army±Depot.±Units±will±not±receive±credit±for±turning±in±serviceable±or±unserviceable±mounts.
± Need±more±information?±Contact±these±folks±at±the±CECOM±Logistics±and±Readiness±Center:
± Regan±Bennett,±inventory±manager,±DSN±648-1374,±(443)±395-1374,±or±email:
regan.e.bennett.civ@mail.mil
± Jenny±Irizarry,±ILS±manager,±DSN±648-1406,±(443)±395-1406,±or±email:
jenny.a.irizarry.civ@mail.mil
± Angel±Acevedo,±engineer,±DSN±648-1407,±(443)±395-1407,±or±email:
angel.l.acevedo30.civ@mail.mil
± Timothy±L.±Langan,±engineer,±DSN±648-1429,±(443)±395-1429,±or±email:
timothy.l.langan.civ@mail.mil
Until recently, your AISI required contractor service
once every 3 years. Now the manufacturer of the AISI,
Trimble
Navigation,
Ltd.,
has
extended
the
service
interval to once every 5 years. The extension covers all
AISIs managed by CECOM.
AISIs under this contract have a sticker that shows the
month and year when the next service is due. Because the
service date is set for every 3 years, the sticker needs to be
updated. Add two years to the date shown on the sticker
and write the new service due date on the sticker.
When±To±Get±Service
± So,±how±do±you±know±when±your±AISI±needs±contractor±service?±Look±at±the±month±
and±year±on±the±sticker.±The±sticker±always±reflects±a±3-year±interval±service±due±date.±To±
get±the±new±5-year±interval±service±due±date,±simply±add±2±years±to±the±date±shown.±For±
example,±if±the±sticker±reads±April±2014,±then±the±new±service±due±date±is±April±2016.
Why±Extend±the±Service±Interval?
The AISI has an internal battery
that supplies power to store data and
Frmware/software. The manufacturer
of
this
battery
has
increased
its
operating
life.
That
in
turn
has
increased the AISI’s time between
services to 5 years.
As
long
as
you
inspect
and
maintain the AISI like it says in TM
5-6675-371-12&P (Jan 09), a 5-year
interval service is all you need.
When
it’s
time
for
contractor
service,
get
instructions
from
CECOM’s Denice Ellis at DSN 848-
2916, (443) 861-2916, or email:
denice.d.ellis.civ@mail.mil
± The±new±mount±allows±you±to±vertically±adjust±your±night±vision±and±lock±it±in±place.
± The±old±helmet±mount,±NSN±
5855-01-551-4525,±will±be±issued±until±stocks±run±out.
Now AISI
needs
contractor
service once
every 5
years
Automated
Integrated
Surveying
Instrument…
Night Vision…
Introducing a
New
Helmet Mount
Longer
Time
Between Services
These NSNs belong
to helmet mounts
that are terminal
items. Don’t use them
with the ACH or CVC
helmet…
Do
You
have an
automated integrated
survey instrument (AISI),
NSN 66
7
5-01-503-35
7
9,
managed by CECOM?
you do?
then
listen
up!
A
new
helmet mount, NSN 5855-01-610-8
7
04,
is available for mounting the AN/PVS-
7
night vision goggles and the AN/PVS-14
monocular night vision device.
The new mount fits on the
advanced combat helmet
(ACH) and the combat vehicle
crewman’s (CVC) helmet.
it uses the
current
front
bracket, NSN 5340-01-509-146
7
.
731 46-47.indd
1-2
8/23/13
1:27 PM
Click here for a copy of this article to save or email.
Click here for a copy of this article to save or email.