TB 9-2320-279-13-1
0012-36
AC HEATER/EVAPORATOR BLOWER OPERATES BUT NO COLD AIR FROM
DUCTS DURING AC OPERATIONS - Continued
DRAFT
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- -
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KNOWN INFO
Power to fan control switch OK.
Blower operates.
AC condenser core not blocked or damaged.
AC compressor belts OK.
AC heater/evaporator core not blocked or
damaged.
AC temperature control switch temperature
probe OK.
Heater cable OK.
AC cable OK.
Defrost cable OK.
AC compressor clutch OK.
AC harness wire 1154 OK.
Low pressure switch OK.
AC harness wire 1158 OK.
High pressure switch OK.
AC harness wire 1156 OK.
AC condenser assembly harness green wire
OK.
AC condenser motor solenoid ground wire
OK.
Fan control switch OK.
Wire 1156 OK.
AC temperature control switch OK.
AC condenser assembly harness black wire
OK.
AC harness wire 1155 OK.
AC condenser motor solenoid OK.
POSSIBLE PROBLEMS
AC condenser motor power wire faulty.
AC condenser motor ground wire faulty.
AC condenser motor faulty.
18.
Is continuity measured
across AC condenser motor
power wire?
Repair AC condenser
motor power wire (see
Appendix A).
Verify
repair, go to Step 27 of
this fault.
NO
YES
Read WARNING on
page 0012-37.
WARNING
TEST OPTIONS
Continuity test.
Multimeter.
REASON FOR QUESTION
If continuity is not measured,
AC condenser motor
power wire is faulty.