TB-9-2320-279-13-1

TECHNICAL BULLETIN; AIR CONDITIONING SYSTEM

OPERATOR’S, UNIT AND DIRECT SUPPORT MAINTENANCE MANUAL, INSTALLATION INSTRUCTIONS, AND REPAIR PARTS AND SPECIAL TOOLS LISTS

DECEMBER 2005

  TB-9-2320-279-13-1 - Page 161 of 524

TB 9-2320-279-13-1
0014-11
AC COMPRESSOR DOES NOT SHUT OFF OR CYCLES CONSTANTLY - Continued
DRAFT
WARNING
Remove rings, bracelets, wristwatches, neck chains, and any other jewelry before working around
vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry or tools may short
across electrical circuits or terminals and cause damage to equipment or severe burns or
electrical shock to personnel.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HEMAC173
CONTINUITY TEST
NOTE:
Do not disconnect wires from AC condenser
motor.
(1) Remove AC condenser motor (WP 0026).
(2) Set multimeter switch to ohms.
(3) Place positive (+) probe of multimeter on red wire at
AC condenser motor terminal.
(4) Place negative (-) probe of multimeter on red wire at
AC condenser motor solenoid terminal.
(a) If there is no continuity, repair AC condenser
motor red wire (see Appendix A).
Verify repair,
go to Step 14 of this fault.
(b) If there is continuity, go to Step 9 of this fault.
CONTINUITY TEST
(1) Set multimeter switch to ohms.
(2) Place positive (+) probe of multimeter on ground
wire at AC condenser motor terminal.
(3) Place negative (-) probe of multimeter on ground
wire at other end.
(a) If there is no continuity, repair AC condenser
motor ground wire (see Appendix A).
Verify
repair, go to Step 14 of this fault.
(b) If there is continuity, replace AC condenser
motor (WP 0026).
Verify repair, go to Step 14 of
this fault.


Back to Top