TB 9-2320-279-13-1
0015-16
AC DOES NOT COOL OR COOLS INADEQUATELY - Continued
DRAFT
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KNOWN INFO
Power to AC system OK.
AC heater/evaporator blower OK.
AC control circuits OK (except for
temperature control and low pressure
switches).
AC low pressure switch OK.
No AC condenser dryer desiccant
contaminant in AC refrigerant system.
No AC refrigerant oil contaminant in AC
refrigerant system.
AC system charge is not low.
No AC system leaks.
Temperature control switch OK.
No air or other contaminant in AC refrigerant
system.
POSSIBLE PROBLEMS
Restricted AC hoses.
AC compressor faulty.
AC condenser core faulty.
Moisture in AC refrigerant system.
AC expansion valve faulty.
AC system overcharged.
AC condenser dryer faulty.
AC evaporator core faulty.
10.
Does AC test set recovery/
recycling manifold gages
indicate high system low-side
pressure?
Go to Step 16 of this
fault.
NO
YES
Read WARNING on
page 0015-17.
WARNING
TEST OPTIONS
Pressure test.
AC test set manifold gage.
REASON FOR QUESTION
To isolate system fault.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
KNOWN INFO
Power to AC system OK.
AC heater/evaporator blower OK.
AC control circuits OK (except for
temperature control and low pressure
switches).
AC low pressure switch OK.
No AC condenser dryer desiccant
contaminant in AC refrigerant system.
No AC refrigerant oil contaminant in AC
refrigerant system.
AC system charge is not low.
No AC system leaks.
Temperature control switch OK.
No air or other contaminant in AC refrigerant
system.
AC condenser dryer OK.
AC evaporator core OK.
POSSIBLE PROBLEMS
Restricted AC hoses.
AC compressor faulty.
AC condenser core faulty.
Moisture in AC refrigerant system.
AC expansion valve faulty.
AC system overcharged.
11.
Does AC test set recovery/
recycling manifold gages
indicate high system high-
side pressure?
Go to Step 14 of this
fault.
NO
YES
Read WARNING on
page 0015-17.
WARNING
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TEST OPTIONS
Pressure test.
AC test set manifold gage.
REASON FOR QUESTION
To isolate system fault.