TB 9-2320-279-13-1
0050-10
AC SYSTEM REFRIGERANT (R-134a) MAINTENANCE - Continued
DRAFT
14. If a leak is found, repair leak as required.
15. Recover refrigerant and repeat evacuation procedure.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
16. Close service hose coupler (11) and service hose coupler (13).
17. Remove blue hose (12) from service valve (5) on hose (6).
18. Remove red hose (10) from service valve (2) on hose (3).
HEMAC192