TB 9-2320-279-13&P
0040
0040-56
NEGATIVE BATTERY CABLES DISCONNECT
Shut off engine
Release two rubber hooks (1).
Remove battery box cover (2) from battery box (3).
There are two types of batteries.
Model A is identified by a 6TN printed on the side of the battery,
while Model B has a 6TL printed on the side of the battery.
Refer to the illustrations for Models A and B for proper positioning of batteries.
The battery caps of
Model B do not protrude through the bracket.
If Models A and B are combined on the same vehicle, all batteries will be positioned as shown for
Model B.
Loosen two nuts (4).
Disconnect two negative cable terminals (5) from battery posts (6).