HEAV
Y
-DUT
Y
WINCH CONTROL
HEAV
Y
-DUT
Y
WINCH CONTROL
VALVE HARNESS
OUT SOLENOID
CONNECTOR
1
2
D
E
C
B
A
HEAV
Y
-DUT
Y
WINCH CONTROL
VALVE HARNESS
REMOTE CONTROL
CONNECTOR
HEAV
Y
-DUT
Y
WINCH CONTROL
STATION
Figure 8.
4. Connect negative (-) probe of multimeter to wire 1682 at heavy-duty winch control valve harness heavy-duty
winch control OUT solenoid connector, terminal 1.
5. Multimeter should display a reading less than 200 ohms. Note reading.
CONDITION/INDICATION
Is continuity measured on heavy-duty winch control valve harness wire 1682?
DECISION
No - Test 9 - Can heavy-duty winch control valve harness wire 1682 be repaired?
Yes - Test 10 - Is continuity measured on heavy-duty winch control valve harness OUT solenoid wire 1435?
TB 9-2320-279-13&P-4
0033
0033-12