5-24.1
TB 9-2320-387-35-1
NOTE
Cables removed for clarity.
8-24.
Install master control station (65) on integrated rack (7) using existing stud (64), washer (56),
washer (55), lockwasher (54), and nut (63), and capscrew (46), lockwasher (54), washer (55), and
washer (56).
Figure 5-33.
63
55
56
65
54
46
54
55
56
7
46. CAPSCREW – B1821BH031F125N – QTY. 1
54. LOCKWASHER – MS35338-45 – QTY. 2
55. WASHER – 2436162 – QTY. 2
56. WASHER – 2436164 – QTY. 2
63. NUT – 9417954 – QTY. 1
65. MASTER CONTROL STATION – A3206623 – QTY. 1
64
Change 1