TB-9-2510-251-13

TECHNICAL BULLETIN

OPERATOR AND FIELD MAINTENANCE; INSTALLATION MANUAL (INCLUDING REPAIR PARTS LIST); FOR ADD-ON-ARMOR (AoA) AIR CONDITIONING

AUGUST 2007

  TB-9-2510-251-13 - Page 216 of 624

2-200
TB 9-2510-251-13
2-2.2
Installation of Air Conditioning Kit to M998 and M998A1 Four-Door with O'Gara Hess
Add-on-Armor (Cont’d).
g. Air Distribution Ducting (Cont’d)
(7)
If air distribution to front is not possible or desired:
a. Cut off female end of 90° elbows so the elbows fit over the square outlets on the plastic
plenum.
b. Attach 90° elbows to plenum.
c.
When air delivery is acceptable, apply a generous quantity of PVC cement
(item 3, Appendix D) to the mating surfaces and secure with screws.
h. Prepare System for Use
1
1
REAR SIDE
ARMOR PLATE
REAR SIDE
ARMOR PLATE
Figure 2-289.
Rear Side Armor Plates
1
REAR CENTER
ARMOR PLATE
Figure 2-290.
Rear Center Armor Plate
(1)
Using foam (1) and duct tape, seal as many cab air leaks as possible.
(2)
Purge and charge air conditioning system (para 4-14).