TB-9-2510-251-13

TECHNICAL BULLETIN

OPERATOR AND FIELD MAINTENANCE; INSTALLATION MANUAL (INCLUDING REPAIR PARTS LIST); FOR ADD-ON-ARMOR (AoA) AIR CONDITIONING

AUGUST 2007

  TB-9-2510-251-13 - Page 285 of 624

TB 9-2510-251-13
Section IV.
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
4-6
General.
Table 4-1 (Unit PMCS table) has been provided so you can keep your equipment in good operating
condition and ready for its primary mission.
4-6.1
Warning, Cautions, and Notes.
Always observe the
WARNINGS, CAUTIONS,
and
NOTES
appearing in your PMCS table.
Warnings
and Cautions appear before applicable procedures.
You must observe
WARNINGS
to prevent serious
injury to yourself and others.
You must observe
CAUTIONS
to prevent your equipment from being
damaged.
You must observe
NOTES
to ensure procedures are performed properly.
4-6.2
Explanation of Table Entries.
4-6.2.1
Item No. Column.
Numbers in this column are for reference.
When completing DA Form
2404 (Equipment Inspection and Maintenance Worksheet) or DD Form 5988E (Equipment Inspection
and Maintenance Worksheet), include the item number for the checks/service indicating a fault.
Item
numbers also appear in the order that you must do checks and services for the intervals listed.
4-6.2.2
Interval Column.
This column tells you when you must do the procedure in the Procedure
column.
Perform procedures such as Monthly or Quarterly at the listed calendar interval.
Perform
procedures designated by number of hours when the equipment has been operated for that many
hours.
4-6.2.3
Item to be Checked or Serviced Column.
This column lists the item to be checked or
serviced.
4-6.2.4
Procedure Column.
This column gives the procedure for checking or servicing the item
listed in the location, item to check/service column.
You must perform the procedure to know if the
vehicle is ready or available for its intended mission or operation.
You must do the procedure at the
time stated in the interval column.
4-6.2.5
Not Fully Mission Capable if:
Column.
Information in this column tells you what faults will
keep your equipment from being capable of performing its primary mission.
If you make checks or
services that show faults listed in this column, do not operate the equipment.
4-6.2.6
Reporting and Correcting Deficiencies.
If Air Conditioning Kit does not perform as
required, refer to Chapter 4, Section V, Unit Troubleshooting.
4-6.3
Other Table Entries.
Be sure to observe all special information and notes that appear in
your table.
4-6.4
Special Instructions.
Preventive maintenance is not limited to performing the checks and
services listed in the PMCS table.
Covering unused receptacles, stowing unused accessories, and
other routine procedures such as equipment inventory, cleaning components, and touch up painting
are not listed in the table.
If a routine check is listed in the Unit PMCS Table (Table 4-1), it is because
experience has shown that problems may occur with this item.
Take along tools and cleaning cloths
needed to perform the required checks and services.
4-9/(4-10 Blank)


Back to Top