TM-10-4930-247-13-P

HEMTT TANKER AIRCRAFT REFUELING SYSTEM MODEL HTARS100

TECHNICAL MANUAL; OPERATOR’S, UNIT AND DIRECT SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

FEBRUARY 1994

  TM-10-4930-247-13-P - Page 144 of 309

TM 10-4930-247-13&P
4-22.
BALL VALVE ASSEMBLY REPAIR -cont.
e.
Assembly.
Refer to figure 4-19.
(1)
Apply anti-seize tape to male threads of female coupling (2) and adapter (4).
(2)
Install ball valve (3) on adapter (4).
(3)
Install female coupling (2) on ball valve (3).
NOTE
Make sure gasket is fully seated in groove of female coupling.
(4)
Install gasket (1) in female coupling (2).
(5)
Remove body of ball valve (3) from vise.
(5A) (Model HTARS101) Install retaining ring (1A) and dust plug (1B) on female coupling (2).
(6)
Install ball valve assembly on fuel hose (para 4-21).
NOTE:
RING (1A) AND PLUG (1B) USED
ON MODEL HTARS 101 ONLY.
Figure 4-19.
Ball Valve Assembly Repair.
Change 4
4-49


Back to Top