TM 10-4930-247-13&P
Table 2-1.
Operator Preventive Maintenance Checks and Services for
Models HTARS100 and HTARS101 - cont.
Item
Location
No.
Interval
Item
Procedure
Not Fully Mission
Check/Service
Capable If:
e.
Inspect for damaged or missing dust
caps.
10
Before
Grounding Rods
a.
Inspect grounding rods for severe
Grounding rod
bends, cracks and corrosion.
missing or broken.
b.
Verify that grounding clamp is securely
connected.
Reconnect if required.
11
Before
Adapters
a.
Inspect for broken or missing adapters.
Required adapters
Make sure that adapters required to connect
broken or missing.
the HTARS to the fuel source are available
and they are in serviceable condition.
b.
Inspect adapters for damaged or missing
Gaskets or seals
seals, gaskets and dust cap.
damaged or missing.
Change 4
2-15