TM-5-2350-262-20-1

ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL; VOLUME 1 OF 3

  TM-5-2350-262-20-1 - Page 490 of 776

TM 5-2350-262-20-1
Change 4
4-139.2
A
Disconnect UNSPRUNG pressure switch electrical
connector (1) from SPRUNG/UNSPRUNG wiring
harness (2).
B
Remove two screws (3), lockwashers (4), and
UNSPRUNG pressure switch (5), with hose (6)
attached, from hull.
Discard lockwashers (4).
C
Remove hose (6) from UNSPRUNG pressure
switch (5).
A
Connect hose (6) to UNSPRUNG pressure switch
(5).
B
Install UNSPRUNG pressure switch (5) on hull with
two new lockwashers (4) and two screws (3).
Coat
shell of electrical connector (2) with silicone
compound and connect UNSPRUNG pressure
switch electrical connector (1) to SPRUNG/
UNSPRUNG wiring harness (2).
FOLLOW-ON TASKS:
Connect negative battery cables (p 4-84).
Retract ejector (TM 5-2350-262-10).
REMOVAL
INSTALLATION


Back to Top