TM 5-2350-262-20-2
4-512
4 minutes before disconnecting any
hose or fitting.
Failure to comply may
result in severe injury to personnel.
Spilled hydraulic oil is very slippery.
Use caution when entering or working
in bowl area.
Wipe up any spilled oil
immediately.
Failure to comply may
result in severe injury to personnel.
Dial in Test 51 on VTM (16).
Press and hold
TEST button (21) on VTM (16) until “CAL”
appears on display (22).
Release TEST button
(21).
Value that appears on display (22)
should be between +450 and -450.
If the value
on display (22) is not within the offset, refer
to TM 9-4910-571-12&P for fault isolation
procedures.
(TM 5-2350-262-10).
(p 3-18).