3-51
TM 5-2350-262-20-3
5
3
4
FORWARD MANIFOLD PRESSURE TEST
NOTE
Have suitable container ready to catch oil.
•
Remove pressure measuring device (1) and connect BUMP STOP CYL-9 hose (2).
•
Disconnect FWD MANF-11-ELB hose (3) from elbow (4) on forward manifold (5).
Cap
hose (3) and install pressure measuring device (1) on elbow (4).
•
Start engine.
With SPRUNG/UNSPRUNG lever in UNSPRUNG, read pressure measuring
device (1).
•
Stop engine; relieve hydraulic pressure.
Remove all test equipment and connect hose.
LEFT FORWARD
MANIFOLD SHOWN
LEFT FORWARD BUMP
STOP SHOWN
1
2
1