APRON WILL NOT RAISE - Continued
o.
Using LINE UP or LINE DOWN button (Figure 7, Item 2), select V1 on the HDC display
(Figure 7, Item 1).
p.
Open V1 on the HDC display (Figure 7, Item 1) by selecting the CHANGE POSITION button
(Figure 7, Item 3) on the HDC control box.
q.
Select V17 on the HDC display (Figure 7, Item 1).
r.
Open V17 on the HDC display (Figure 7, Item 1) by selecting the CHANGE POSITION button
(Figure 7, Item 3) on the HDC control box.
T00610HDC
3
2
1
Figure 7.
Directional Control Valve (DCV) Bank.
CONDITION/INDICATION
Can circuit 19 relief valve be set to develop 3,500 psi (24,131 kPa)?
DECISION
YES - Verify problem is solved.
NO - Replace Directional Control Valve (DCV) bank (TM 5-2350-262-20).
TM 5-2350-378-23&P
0008
0008-8