TM-5-2350-378-23-P

ARMORED COMBAT EARTHMOVER (ACE), M9; HYDRAULIC DIAGNOSTIC CENTER

TECHNICAL MANUAL; FIELD MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

JUNE 2012

  TM-5-2350-378-23-P - Page 136 of 644

EJECTOR DOES NOT EXTEND OR RETRACT - Continued
STEP
3.
Perform suction strainer check.
a.
Slowly loosen hydraulic tank dipstick (Figure 3, Item 1) to release pressure and remove dipstick.
b.
Remove suction strainer (Figure 3, Item 2) and inspect for clogged ports or obstructions.
c.
If dirt, obstructions, or debris is found, clear and clean suction strainer (Figure 3, Item 2).
d.
Replace suction strainer (Figure 3, Item 2) and dipstick (Figure 3, Item 1).
1
T00905HDC
2
Figure 3.
Suction Strainer.
CONDITION/INDICATION
Is suction strainer clean?
DECISION
YES - Go to Step (4).
NO - Clean suction strainer. Verify problem is solved.
TM 5-2350-378-23&P
0011
0011-4