TM-5-2350-378-23-P

ARMORED COMBAT EARTHMOVER (ACE), M9; HYDRAULIC DIAGNOSTIC CENTER

TECHNICAL MANUAL; FIELD MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

JUNE 2012

  TM-5-2350-378-23-P - Page 291 of 644

VEHICLE DOES NOT RESPOND TO OPERATOR CONTROLS - Continued
CONDITION/INDICATION
Can main relief valve be adjusted to 3,950-4,050 psi (27,235-27,925 kPa)?
DECISION
YES - Verify problem with operator.
NO - Replace DCV bank (TM 5-2350-262-20).
END OF WORK PACKAGE
TM 5-2350-378-23&P
0018
0018-13/14 blank


Back to Top