REMOVAL
WARNING
Do not operate ejector when personnel are in bowl. Do not work in bowl unless ejector
lock is engaged. Failure to comply may result in severe injury or death to personnel.
Do not stand or work in bowl area unless ejector lock is engaged. Do not stand in bowl
to observe roller guide travels. Failure to comply may result in severe injury or death to
personnel.
When folding dozer blade, work on blade latches from side of vehicle only. Do not stand
in front of dozer blade while retracting ejector. Failure to comply may result in severe
injury or death to personnel.
1.
At the main hydraulic pump left and right high-pressure filter area, remove wiring harness W2 connector P3
(Figure 1, Item 6) from transducer T3 (Figure 1, Item 5), wiring harness W2 connector P4 (Figure 1, Item 4)
from transducer T4 (Figure 1, Item 3), and wiring harness W2 connector P30 (Figure 1, Item 1) from transducer
T12 (Figure 1, Item 2).
6
5
4
3
1
2
M0012HDC
Figure 1.
Wiring Harness W2 from Filter Area Removal.