TM-5-2350-378-24-P

HYDRAULIC DIAGNOSTIC CENTER (HDC) SUPPORTING ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

  TM-5-2350-378-24-P - Page 445 of 790

TM 5--2350--378--24&P
0019 00--12
VEHICLE DOES NOT RESPOND TO DRIVER CONTROLS -- Continued
0019 00
YES
from block 8
12
Verify problem with operator.
13
Replace directional control valve bank
(TM 5--2350--262--20--2).
YES
NO
10
Is transducer T--3 pressure between 3,950--4,050
psi (27,235--27,925 kPa)?
Perform main relief valve test using the HDC.
YES
NO
11
Can main relief valve be adjusted to
3,950--4,050 psi (27,235--27,925 kPa)?
Perform main relief valve adjustment
using the HDC.


Back to Top