ORGANIZATIONAL TROUBLESHOOTINGING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
clockwise to on position and press ENGINE START button (4) for 1 second. Check for 11 to 13
vdc on multimeter.
Have assistant rotate KEY SWITCH (3) counterclockwise to off position.
Disconnect test leads.
a
If multimeter reads no voltage, replace automatic override module (1) (page 2-877).
b
If multimeter reads 11 to 13 vdc, go to step 23.
2-81