20. ALL LIGHTS DO NOT WORK - CONTINUED.
Step 13. Set multimeter to ohms scale and adjust to 0 ohms.
Position headlight switch (1) with slot (2) facing 12
o’clock.
Push switch handle (3) down to 6 o’clock position.
Connect red test lead to terminal (4) and black
test lead to terminal (5).
Check for 0 ohms on multimeter.
Move red test lead to terminal (6) and black
test lead to terminal (7).
Check for 0 ohms on multimeter.
Move red test lead to terminal (8) and black
test lead to terminal (9).
Check for 0 ohms on multimeter.
Disconnect test leads.
If multimeter reads no continuity on either terminals (5, 7, or 9), replace headlight switch (1) (page 2-