TM 5-3805.254.20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
b.
If multimeter reads 11 to 13 vdc, go to step 5.
Step 4. Test fuse (6) as follows: Using fuse puller, remove fuse (6).
Set multimeter to ohms scale and adjust to 0 ohms.
Connect red test lead to fuse end (7) and black test lead to fuse end (8).
Check for 0 ohms on multimeter.
Disconnect test leads.
a. If multimeter reads no continuity, replace fuse (6) (page 2-424).
b. If multimeter reads O ohms, install fuse (6).
Connect batteries (page 2-424) and go to step 5.
2-207