TM-5-3805-254-20-1

TRUCK, DUMP, 20 TON, 6X4, ON-OFF HIGHWAY 71,000 GVW, IHC MODEL F-5070 (CCE)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL VOLUME 1 OF 2

JANUARY 1988

  TM-5-3805-254-20-1 - Page 347 of 790

TM 5-3805-254-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 6.Test jumper wire (8) as follows: Using multimeter, set to ohms scale and adjust to 0 ohms.
Connect red test lead to terminal (3) on stoplight switch (1) and black test lead to terminal (9) on
stoplight switch (7).
Check for 0 ohms on multimeter.
Disconnect test leads.
a.If multimeter reads no continuity, jumper wire (8) must be replaced.
Notify Direct
Support Maintenance.
b.
If multimeter reads 0 ohms, connect batteries (page 2-
424) and go to step 7.
2-277


Back to Top