TM 5-3805-254-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 3. Check air compressor governor (3) for proper operation as follows: start engine (TM 5-3805-254-
10), wait for air compressor (4) to cut out.
Note air pressure when air compressor (4) cuts out
and air compressor governor (3) exhaust air pressure out of exhaust port.
Air compressor
governor (3) should discharge air pressure out of exhaust port (5) at 120 to 125 psi (827 to 861
kPa).
If air compressor governor (3) does not exhaust air pressure out of
exhaust port (5) at 120 to 125 psi (827 to 861 kPa), notify Direct
Support Maintenance.
TA243919
2-345


Back to Top