TM 5-3805-254-20-2
TAIL AND PANEL LIGHT 20 AMP CIRCUIT BREAKER - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
3.
Circuit breaker
Circuit breaker (1)
Slide up and take out.
panel (7)
INSTALLATION
CAUTION
Use only correct amperage circuit breaker, to prevent damage to equipment.
Use care when working behind right instrument panel pad to prevent breaking or disconnecting wires.
4.
Circuit breaker
Circuit breaker (1)
Slide down into place.
panel (7)
5.
Circuit breaker (1)
Flat washer (6), two
Screw on and tighten using 318-inch box-
new lockwashers (5),
end wrench.
and two nuts (4)
6.
Wire (3) and new
a.
Put wire in place.
self-locking nut (2)
b.
Screw on and tighten using 318-inch
box-end wrench.
c.
Take off tag.
d.
Get rid of tag.
TA244183
2-761