TM-5-3805-254-20-2

TRUCK, DUMP, 20 TON, 6X4, ON-OFF HIGHWAY 71,000 GVW, IHC MODEL F-5070 (CCE)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL VOLUME 2 OF 2

JANUARY 1988

  TM-5-3805-254-20-2 - Page 347 of 971

TM 5-3805-254-20-2
DRY AIR RESERVOIR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
26.
Dry air
a.
Look for cracks or broken welds.
reservoir (1)
b.
Look for stripped or broken step
studs (3).
c.
Look for stripped or cracked elbow and
plug bosses (4).
d.
Look for stripped or cracked draincock
bosses (5).
e.
Using flashlight, look inside for exces-
sive rust or corrosion.
27.
Step (2)
a.
Look for cracks, breaks, or bends.
b.
Look for distorted step stud holes.
28.
All threaded parts
Look for damaged threads or rounded
heads.
TA244321
2-981


Back to Top