TM 5-3805-254-20-2
BACKUP LIGHT SWITCH - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION
3.
Transmission (1)
Backup light
a Clean pipe threads with wiping rag.
switch (2)
b Wrap pipe threads with antiseizing tape
(page 2-424).
c Screw in and tighten using 1-inch open-
end wrench.
4.
Backup light
Wire (3)
Push on.
switch (2)
NOTE
FOLLOW-ON MAINTENANCE: Fill transmission (page 2-900).
TASK ENDS HERE
NEUTRAL SAFETY SWITCH
This task covers:
a.
Removal (page 2-691)
b.
Installation (page 2-692)
TA244144
2-690