  TM-5-3805-254-34 - Page 121 of 727

TM 5-3805-254-34
5-5.
STARTER MOTOR SOLENOID REPLACEMENT (Con’t).
5.
Remove screw (15), ground lead (14), and clamp (16) from bracket (17).
6.
Remove four screws (12) from solenoid (13).
7.
Remove solenoid (13) from plunger (18) and starter (19).
b.
INSTALLATION
1.
Position solenoid (13) on starter (19) and
plunger (18).
2.
Install four screws (12) on solenoid (13).
3.
Install clamp (16) and ground lead (14) on
bracket (17) with screw (15).
4.
Position connector (6) on two terminals (5 and
11).
5.
Install new lockwasher (10) and nut (9) on
terminal (11).
6.
Install new lockwasher (7) and nut (8) on
terminal (5).
TA703729
5-36


Back to Top