TM-5-3895-371-10

BITUMINOUS DISTRIBUTOR M918, MODEL D-63

TECHNICAL MANUAL; OPERATION INSTRUCTIONS

OCTOBER 1979

  TM-5-3895-371-10 - Page 69 of 103

TM 5-3895-371-10
Table 3-1. Operator/Crew Preventive Maintenance Checks and Services - Continued
B - Before
D - During
A - After
W - Weekly
M - Monthly
Item
No.
B
Interval
D
A
W M
Procedure:
ITEM TO BE INSPECTED
Check For And Have Repaired,
Filled Or Adjusted As Needed
FOR READINESS REPORTING
Equipment Is Not Ready/
Available If:
20
Check fuel tank for leaks
Class III leaks are evident
21
Check blower burner fuel line
strainer. If clogged, clean it.
22
Check blower air cleaner. If
oil is dirty, change oil.
23
Check burner valve strainer.
If clogged, clean it.
24
Check heater burners and flues
for insecure mounting.
Portable Burner
25
Check burner coil and vapor-
izing jet. If dirty, clean it.
26
Check portable burner gage.
Best operation at 45 psi.
Indicator is inoperative
Bitumeter Wheel Assembly
27
Check bitumeter wheel for
secure mounting and proper
operation.
28
Check bitumeter wheel air-
gage (at wheel) activated
In cab and 120 psi is mini-
mum pressure.
Indicator is inoperative
or gage does not show
pressure.
29
Check recording bitumeter.
Records in ft per minute
and feet traveled.
30
Check air lines for leaks.
Spray Bar
31
Check nozzle slots for cor-
rect angle (30 degrees) and
correct height above road
(12 inches above road).
3-7