TM 5-3895-372-20
AIR SYSTEM.
11-11. TIMING DEVICE MAINTENANCE (Continued).
LOCATION/ITEM
ACTION
REMARKS
A. REMOVAL (Continued).
2.
Cam collar (16) and
Loosen two set screws (14) and
locking collar (15).
remove from meter feeder shaft (11).
3.
Mounting bracket (7).
Remove two capscrews (6) and lift
off end of cement meter feeder (10).
B. CLEANING AND INSPECTION.
4.
All parts.
a.Remove cement build-up with
a wire brush or scraper.
b.Inspect for damage and excessive
wear and replace as necessary.
C. INSTALLATION.
5.
Mounting bracket (7).
Aline mounting holes with holes in
cement meter feeder (10) and install
two capscrews (6).
6.
Cam collar (16) and
Install on meter feeder shaft (11) and
locking collar (15).
tighten two setscrews (14)-
7.
Two air valves (5).
a.Install on mounting bracket (7) and
loosely secure with four machine
screws (9), flat washers (8), lock-
washers (4), and hex nuts (3).
b.Apply liquid teflon to threads and
install two pipe nipples (2), pipe
tees (1), pipe nipple (12), and pipe
elbow (13).
c.Adjust timing device, refer to para
11-10.
NOTE
Follow-on maintenance action required: Install air lines, refer to para 11-12C.
D. OPERATIONAL CHECK.
8.
Mixer body.
Start up (refer to TM 5-3895-372-10
and TM 9-2320-27:10). Check oper-
ation of vibrators. Shut down vehicle
and close access panel,
11-32