0119-19
DRAFT
0119
TFFT04020
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 25.
Turn battery disconnect switch to OFF position (WP 0007).
Remove skid plate grille
(WP 0550).
Disconnect main wire harness pump operator’s panel wire harness
connector DO2.
Disconnect main wire harness main 5 wire harness connector.
With a
test lead set check for continuity across main wire harness wire 2855 (red) from main
wire harness pump operator’s panel wire harness connector DO2, terminal 13 to main
wire harness main 5 wire harness connector, terminal 2.
a.
If there is continuity, repair wire 2855 in cab pump control wire harness
if repairable (TM 9-2320-325-14&P), or replace cab pump control wire
harness (WP 0443).
b.
If there is no continuity, repair wire 2855 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0455).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION