Step 40.
Remove skid plate grille (WP 0550).
Disconnect main wire harness main 5 connector.
With a test lead set, check for continuity across main wire harness wire 2855 (red) from
main wire harness main 5 connector, terminal 2 to main wire harness pump operator’s
panel wire harness connector DO2, terminal 13.
a.
If there is continuity, repair wire 2855 in cab pump control wire harness
if repairable (TM 9-2320-325-14&P), or replace cab pump control wire
harness (WP 0443).
b.
If there is no continuity, repair wire 2855 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0455).